Rated input: 3-phase 3-wire mode, 3-phase 4-wire mode;
380, 400, 415, 480 VAC, 220, 230, 240, 277 VAC.
Ideal for 3-phase Voltage Asymmetry.
Monitoring for Industrial Facilities and Equipment.
Greater resistance to inverter noise.
Monitor voltage asymmetry, phase sequence, and phase,
loss for three-phase 3-wire or 4-wire power supplies with just one Unit OMRON K8AB-PH1 PDF datasheet.
Switch setting for 3-phase 3-wire or 3-phase 4-wire power supply
K8AB-PH1
One SPDT output relay, 5 A at 250 VAC (resistive load).
World-wide power specifications supported by one Unit (switchable).
Relay status can be monitored using LED indicator. Power supply voltage: 100 to 240 VAC.
Ideal for Liquid Level Control in.
Industrial Facilities and Equipment OMRON K8AB-PH1 PDF datasheet.
Self-holding circuit implemented with circuit processing that is,
not depending on external wiring.
Switch between water supply and discharge with a DIP switch setting.
Sensitivity adjustment of operating resistance from 10 k to 100,
kΩ for application to a wide range of liquids.
Prevents chattering of relay contacts that occurs with ripples.
Easy wiring with ferrules OMRON K8AB-PH1 PDF datasheet.
Use 2 × 2.5 mm2 solid wire or 2 × 1.5 mm2 ferrules.
Applicable as a floatless switch. Static voltage relay.
K2VR-S/K2VA-S type, high action reliability disk with static type UVR/OVR.
Accurate work through high reliability semiconductor circuits.
Type K2VU-S1 is the output contact, but will be closed when the voltage is not enough,
Therefore, the locking time sequence circuit of the circuit breaker is not required.
Within the hidden from the start to the 2S timer, can easily adjust the time.
The control power of the relay is not needed, which avoids the trouble of wiring.
Time specification: Instantaneous type.
Current setting range: 50 to 160 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operattion time,
is indicated from the start of operation K8AB-PH1 PDF catalog.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequeency, basic,
frequency, and load conditions K8AB-PH1 PDF catalog. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,