Supply voltage: 24 VDC.
Time-limit contact: 4PDT(Twin contacts).
Long-time range model(0.1 min to 10 h).
Miniature Timer with Multiple Time.
Ranges and Multiple Operating Modes.
Minimizes stock.
Pin configuration compatible with MY Power Relay.
Standard multiple operating modes and multiple time ranges OMRON H7CX-R11WD1-N PDF datasheet.
Conforms to EN 61812-1 and IEC 60664-1 for Low Voltage,
and EMC Directives
H7CX-R11WD1-N A DIN 72 x 72 mm Best-selling Counter.
Easy setting with thumbwheel switches.
A draw-out construction enables maintenance without rewiring.
Models with 2-, 4-, 6-, or 8-digit displays are also available.
Total Counter models are also Available.
Complies with UL and CSA Marking. Operation/resetting system: Time-limit operation/self-resetting OMRON H7CX-R11WD1-N PDF datasheet.
Operation mode: ON-delay operation.
Terminal: 8-pin round socket.
Time-limit contact: DPDT.
Instantaneous contact: --.
Mounting: Surface mounting/track mounting; Flush mounting.
DIN-sized (48 x 48, 45 x 75 mm) Timer with.
Digital Setting and LCD Display.
Dual power supplies for free AC/DC.
Eight operation modes selectable with one unit.
Any desired time can be set digitally within a range from 0 OMRON H7CX-R11WD1-N PDF datasheet. 1,
seconds to 9,990 hrs.
Four external signal inputs.
ON/OFF indicator for control output and bar indicator for,
remaining time.
Conforms to UL, CSA, and CE marking. Supply voltage: 24, 100 to 120, 200 to 230 VAC; 12, 24, 48, 100 to 110, 125 VDC.
Time-limit contact: 4PDT.
Short-time range model (0.1 s to 10 min).
Miniature Timer with Multiple Time Ranges,
and Multiple Operating Modes.
UL listed when used with a Push-In Plus Terminal Block Socket.
Conforms to CSA, CE Marking, LR, and CCC.
Black design with power supply terminals on top and contact output,
terminals on bottom.
Standard multiple operating modes and multiple time ranges.
Pin configuration compatible with MY Power Relay.
Minimizes stock. Nine Built-in Counters/Timers to.
Measure Equipment Operating.
Cycles and Times and Forecast.
Maintenance Timing.
Provides up to nine counters or accumulative timers.
(Counter and timer functions can be used at the same time.)
Individual forecast outputs to indicate maintenance timing.
Pree-forecast display and machine stoppage output provided H7CX-R11WD1-N PDF catalog.
IP54 oil-proof type at setting area for resistance to oil and water.
Separate digit keys to easily change settings.
Compact, short-body: 72 × 72 × 79 mm (DIN).
Keey protection function prevents incorrect operation H7CX-R11WD1-N PDF catalog.
Multiple outputs: NPN/PNP.
Directly connectable to 2-wire DC sensors.
Complies with UL and CSA.