Timer input: PNP/NPN universal DC voltage input(4.5 to 30 VDC).
Display: 7-segment LCD.
Time range: 999h59min59s ←→ 9999h59.9min(switchable); Light-gray body.
Seven digits, time range 0 to 3999d23.9h.
Dual time range: 999999.9 ←→ 3999d23.9h or,
999h59m59s ←→ 9999h59.9m. Control output: Contact output: DPDT (time-limit output) OMRON H3AM-NSR-B PDF catalog.
Supply voltage: 220 VAC (50/60 Hz).
11-pin models
H3AM-NSR-B
Solid-state Timer with Valuable Multiple-time.
Ranges and Multiple-operating Modes.
Handles a wide range of applications through eight operating modes.
With H3BA-N8H models, the output type can be switched.
between time-limit DPDT and time-limit SPDT + instantaneous.
SPDT using a selector.
Setting rings (order separately) to enable consistent settings OMRON H3AM-NSR-B PDF catalog.
and to limit the setting range.
Panel Covers (order separately) to enable various panel.
designs.
CE marking.
UL, CSA and CCC certification, conforms to LR. Type: H5CX-A series.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s,
0.1 to 999.9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0 OMRON H3AM-NSR-B PDF catalog. 1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode, A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2.
External connections: 11-pin socket.
Input: Signal, Reset, Gate (NPN/PNP input).
Output: Transistor output(SPST).
Supply voltage: 100 to 240 VAC.
The Timer with the Shortest Body,
in the Industry. Daily Time Control with Simple Operations,
Specify the operation days.
(However, you can set only one pattern of operation days,
and specified days.)
Up to 12 ON/OFF operations (24 for pulse-output operation).
Special holidays can be handled easily with the holiday,
setting function.
Adjustments for sudden schedule changes can be made eaas,
ily using output override and automatic return operation H3AM-NSR-B PDF datasheet.
The operation program can be checked easily with the program check function.
Enables pulse output operation and summer time setting.
Incorporates finger-safe terminals H3AM-NSR-B PDF datasheet.
Conforms to UL, CSA, and CE marking.
Meets a variety of mounting requirements: flush mounting,
surface mounting, and DIN track mounting.