Input capacity: 16 points.
Rated current (ON current): 0.5 A/output,
4.0 A/common.
Internal I/O common: NPN.
Residual voltage: 1.2 V max.
(0.5 ADC, between each output,
terminal and the G terminal)
Leakage current: 0.1 mA max.
ON delay: 0.5 ms max.
OFF delay: 1.5 ms max.
Number of circuits per common:
8 points/common OMRON G9SX-NSA222-T03-RT PDF catalog.
Output indicators: LED display (yellow)
G9SX-NSA222-T03-RT
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply.
Output device supply current: 100 mA/point.
Unit power supply current consumption: 90 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
I/O power supply current consumption: 5 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
Weight: 370 g max OMRON G9SX-NSA222-T03-RT PDF catalog.
Expansion functions: No.
Output handling for communications errors:
Select either hold or clear.
Short-circuit protection function: No.
A common terminal is provided for each contact.
It eliminate the needs for relay terminal blocks.
It is unnecessary to share the common terminal,
among multiple contacts.
Easy-to-find wiring locations.
Detachable screw terminal block facilitates the maintenance OMRON G9SX-NSA222-T03-RT PDF catalog.
Input response time can be switched for high-speed processing.
Selectable node address setting methods: setting with rotary,
switch and with tool software.
When setting the nodes with rotary switch, setting is easy and,
node identification becomes possible for maintenance. Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: NO.
Rated output load: 3 A at 100 to 240 VAC (See note 1.).
Rated input voltage: 4 to 24 VDC.
International Standards for G3F Series,
Same Profile as MY Power Relays.
Shape-compatible with mechanical relays.
Certified by UL, CSA, and VDE (model numbers with a suffix of“-VD”).
Socket type, same size as MY Power Relays.
Operation indicator provided to confirm input.
(model numbers with “N” before the suffix). Number of phases: Three-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Type: DIN track mounting *2.
Applicable load: 15 A, 100 to 240 VAC.
Number of pole: 2.
Compact, Slim-profile SSRs with Heat Sinks.
Solid State Contactors for Three-phase.
Heaters Reduced Installation Work.
with DIN Track Mounting.
RoHS compliant.
Surge pass prrotection improved surge dielectric strength,
for output currents G9SX-NSA222-T03-RT PDF datasheet. (OMRON testing).
Slim design with 3-phase output and built-in heat sinks.
DIN Track mounting types and screw mounting types are available.
All DIIN Track mounting types mount to DIN Track G9SX-NSA222-T03-RT PDF datasheet.
(applicable DIN Track: TR35-15Fe (IEC 60715)).
Conforms to UL, CSA, and EN standards (TÜV certification).