E32-A07E2 type: special beam type; liquid level detection,
Specialty: the detection range of the detection location is scattered less than 0.2mm,
Bending radius (mm): R25.
Fiber element for meeting diversified needsSize: 48 x 96mm.
Ontology: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V) E5CN-CQ203L-FLK PDF datasheet .
Shell color: black.
Control output: current output
E5CN-CQ203L-FLK
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of / E5CN-CQ203L-FLK PDF datasheet .
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay E5CN-CQ203L-FLK PDF datasheet .
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc OMRON E5CN-CQ203L-FLK PDF catalog. , can be a key operation. Ontology: program type.
Size: 48 x 96mm.
Type: basic type (1 input).
Control mode: standard control, heating and cooling control OMRON E5CN-CQ203L-FLK PDF catalog.
Output (control / transfer) points: 2 points (pulse + pulse / current).
Output (SUB) points: 4 points.
Event entry point: 2.
Serial communication: -.
New high speed, high precision digital regulator (Cheng Xuxing)!
Can be set up to 32 kinds of procedures.
1 units can be coordinated to run up to 4 channels OMRON E5CN-CQ203L-FLK PDF catalog.
High speed acquisition of 50ms.
With CX-Thermo on the computer easily set. Sensing method: Retro reflective.
Appearance: Horizontal.
Connection method: Pre-wired (22 m) E5CN-CQ203L-FLK datasheet.
Sensing distance: 300 mm [100 mm].
Model: NPN output.
Recommended application: Flat object,
Detecting glass wafers and LCD glass circuit boards, Ideal;
Cylindrical object,
Detecting plastic bottles and otherr transparent containers, Ideal E5CN-CQ203L-FLK PDF datasheet .
Ideal for Detecting Glass Wafers,
and Other Transparent Objects,
Detects glass wafers and LCD glass circuit boards.