Power: 45kw.
Purpose: to suppress the power harmonics.
Improve the power factor, reduce the input side of the high harmonic current.
Make sure that this option is installed in the FR-A820-03800 (75K) and FR-A840-02160 (75K) and above capacity and above capacity.
At the same time the installation options in the use of 75kW and above motor MITSUBISHI FX3G-14MR/ES-A PDF catalog. (the IP55 series has a built-in DC reactor
FX3G-14MR/ES-A)
According to the motor power used to select the DC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.) Power: 30kw.
Voltage: 200V.
There are 100% braking torque output in continuous regeneration, which can correspond to the continuous regeneration operation of the pipeline control MITSUBISHI FX3G-14MR/ES-A PDF catalog.
There is no need to install the braking unit for each frequency converter, which can reduce the comprehensive space and reduce the comprehensive cost.
Renewable energy can be used for other frequency converter, excess energy back to the grid, to achieve energy saving. MITSUBISHI inverter series: FR-A820.
Voltage level: three phase 200V.
Power: 7.5kw.
SLD converter rated current: 49A MITSUBISHI FX3G-14MR/ES-A PDF catalog.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Parameters can be selected by 4 different rated current and different overload rating (SLD (ultra light load) rated, LD (light load) rating, ND (general load) rating, HD (weight).
Type load) for selection.
You can choose the most suitable frequency converter for use; and by selecting a transducer with a SLD or LD rated level,
Be able to reduce the size of the device (compared with the FR-A700 series, to reduce the volume of equipment).
For applications that require high torque at low speeds, the HD rating is the most suitable.
The controller is used to control and monitor the frequency converter through the network.
Standard corresponding RS-485 communication (MITSUBISHI converter protocol, Modbus-RTU protocol) data transmission speed up to 115200bps. Function: AnyWireASLINK master station.
DC5V internal consumption current: 130mA. Protocol: SLMP, TCP/IP, UDP, SNTP.
Communication mode: full duplex / half duplex.
At the same time can opeen a few: 4 connection FX3G-14MR/ES-A PDF datasheet.
Weight: 0.3kg.
Can be low cost will be connected to the FX3 series Ethernet.
Support data monitoring, can monitor the basic unit through the computer browser,
Remote maintenance can be carried outt by Works2 GX in a place far from the scene FX3G-14MR/ES-A PDF datasheet.
Connect FX3SA, FX3S, FX3GA, FX3G, FX3U host, you need to convert the adapter or function expansion board.