LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Catalog Download >> E5EC-CC4ASM-014
E5EC-CC4ASM-014 PDF catalog OMRON E5EC-CC4ASM-014 datasheet PDF datasheet
Product model: E5EC-CC4ASM-014
Name: Digital temperature controller
Brand: OMRON
Sort: PDF datasheet
File language: English
Size: 48 * 48mm, terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: linear voltage output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -.
Event input points: - OMRON E5EC-CC4ASM-014 PDF datasheet.
Transfer output: output (using control output).
Communication: - E5EC-CC4ASM-014
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms OMRON E5EC-CC4ASM-014 PDF datasheet.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output OMRON E5EC-CC4ASM-014 PDF datasheet.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. E32-ZD200 detection distance
Pair shootingThe main body: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: silver.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement E5EC-CC4ASM-014 PDF catalog.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV E5EC-CC4ASM-014 PDF catalog.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Related products
OMRON
Digital temperature controller
E5EC-CC2DSM-013
OMRON Digital temperature controller E5EC-CC2DSM-013
Size: 48 x 96mm. Control output 1: rela
OMRON
Digital temperature controller
E5EC-CX4ASM-014
OMRON Digital temperature controller E5EC-CX4ASM-014
Size: 48 x 96mm. Control output 1: line
OMRON
Digital temperature controller
E5EC-CC4ASM-014
OMRON Digital temperature controller E5EC-CC4ASM-014
Size: 48 x 96mm. Control output 1: rela
OMRON
Digital temperature controller
E5EC-CX2ASM-014
OMRON Digital temperature controller E5EC-CX2ASM-014