LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Catalog Download >> E3JK-TN12 2M
E3JK-TN12 2M PDF catalog OMRON E3JK-TN12 2M datasheet PDF datasheet
Product model: E3JK-TN12 2M
Name: Built-in Power Supply Photoelectric Sensor
Brand: OMRON
Sort: PDF datasheet
File language: English
Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: current output.
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points OMRON E3JK-TN12 2M PDF datasheet.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use E3JK-TN12 2M
Event entry point: 2.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance OMRON E3JK-TN12 2M PDF datasheet.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation OMRON E3JK-TN12 2M PDF datasheet.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Size: 48 x 96mm.
Type: Platinum resistance.
Adjustment mode: ON/OFF action or PID action.
Alarm: single alarm.
Output: relay output.
Temperature controller with single alarm output.
SV and PV can be displayed at the same time.
Multiple temperature range allows setting the optimum temperature range.
The protection function can prevent the error in operation. Control output: Voltage output.
Auxiliary output: Two.
Communications: --.
Heater burnot: Detection for Single-phase heater.
Event inputs: One.
Power supply voltage: 100 to 240 VAC.
The E5DC-800 Mounts to DIN Track and Is Ideal,
for Connections to HMIs and PLCs.
It provides the Same Easy Operation and,
Advanced Performance as the Rest of the,
E5@C-800 Series.
A slim body at 85 × 22.5 mm (D × W) that fits into narrow control,
panels and mounts to DIN Track.
Removable terminal block for easy replacement to simplify maintenance.
Higgh-speed sampling at 50 ms for applications with high-speed,
temperature increases E3JK-TN12 2M PDF catalog.
Easy connections to a PLC with programless communications.
Models are available with up to 2 auxiliary outputs and 1 event input to,
commplete basic functions E3JK-TN12 2M PDF catalog.
A white PV display (height: 8.5 mm) is easy to read when setting up,
checking alarms, and making settings in a control panel.
Related products
OMRON
Photoelectric sensors
E3FA-DN12 2M
OMRON Photoelectric sensors E3FA-DN12 2M
Sensor type: Diffuse-reflective. Sensin
OMRON
DC type photoelectric switch (power supply)
E3JK-T91J
OMRON DC type photoelectric switch (power supply) E3JK-T91J
E3JK-T91J for firing type, E3JK communic
OMRON
DC type photoelectric switch (power supply)
E3JK-T31
OMRON DC type photoelectric switch (power supply) E3JK-T31
E3JK-T31 for firing type, E3JK direct cu