Size: 48 x 96mm.
Control output 1: linear current output.
Control output 2: voltage output (SSR driver).
Auxiliary output: 4 points (auxiliary output 2, 1 common, auxiliary output 3, 4 public general).
Power supply voltage: AC100 ~ 240V.
Terminal shape: screw terminal table type.
Input category: full range multi input OMRON High Precision Positioning Inductive Proximity Sensor PDF datasheet
E2C-EDA21 2M
Heating wire break, SSR fault detection function: 2 point (three phase heater).
Communication: RS-485.
Event input: 2 points.
Remote SP input: -.
Transfer output: -.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm OMRON High Precision Positioning Inductive Proximity Sensor PDF datasheet.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications OMRON High Precision Positioning Inductive Proximity Sensor PDF datasheet.
The main body is short, the thickness is only 60mm E2C-EDA21 2M PDF datasheet.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC) E2C-EDA21 2M PDF datasheet.
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve. Detection methods: the firing pattern.
Detection range: 500mm.
Purpose: small,
Small thin space probe;
Interference prevention function with close installationSize: M8(Stainless steel)(See note 2 E2C-EDA21 2M PDF datasheet. ); Double; Shielded.
Sensing distance: 2 mm.
Connecting method (See note 1.): M8 Connector (3-pin).
Body length: Long.
Output configuration: NPN.
Operation mode NO.
A new generation in global applications. Size: 48 x 48mm.
Body: terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The failure detection function of the heater with the broken line and SSR: -.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensorss E2C-EDA21 2M PDF catalog.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to eexecute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault