Size: M12, Shielded.
Sensing distance: 4.0 mm.
Connection: Pre-wired.
Body material: Brass.
Thread length (overall length): 34 (50).
Output configuration: NPN.
Operation mode NC.
Safe Mounting with Greater.
Sensing Distance.
Ensures a sensing distance approximately 1.5 to 2,
times larger than that of any conventional OMRON Sensor OMRON Proximity Sensors PDF datasheet.
Problems such as the collision of workpieces are eliminated
E2B-S08LS02-MC-C2
Full range of standard sizes (M8, M12, M18 and,
M30; both long and short barrels).
Modular construction simplifies customization. Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: -- OMRON Proximity Sensors PDF datasheet.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-232C.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0 OMRON Proximity Sensors PDF datasheet. 3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks E2B-S08LS02-MC-C2 PDF datasheet.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E2B-S08LS02-MC-C2 PDF datasheet.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays E2B-S08LS02-MC-C2 PDF datasheet.
Models are available with one or two alarm outputs. Size: 48 * 48mm, terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(auttomatic / manual, RUN/RESET, alarm),
Interactive display PV/SV E2B-S08LS02-MC-C2 PDF catalog.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can performm flexible contact output OMRON Proximity Sensors PDF datasheet.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.