LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Catalog Download >> AX80Y80C
DC input / transistor output module AX80Y80C datasheet PDF datasheet MITSUBISHI AX80Y80C PDF catalog
Product model: AX80Y80C
Name: DC input / transistor output module
Brand: MITSUBISHI
Sort: PDF datasheet
File language: English
Cable length: 3 meters.
Long distance CPU extension cable.
For QnA/ACPU/ motion control and GOT connection. Output points: 24 points.
Voltage: DC24V/AC240V, 2A/1 point, 5A/1 public end.
OFF leakage current: 0.1mA.
Output type: relay output.
Response time: 12ms.
8 point /1 a public side.
36 point terminal station AX80Y80C PDF datasheet .
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor AX80Y80C
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal AX80Y80C PDF datasheet .
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian AX80Y80C PDF datasheet .
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process MITSUBISHI AX80Y80C PDF catalog.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points MITSUBISHI AX80Y80C PDF catalog MITSUBISHI AX80Y80C PDF catalog. Self service (IN, OUT): SI optical cable.
Other aspects (IN, OUT): SI optical cable.
Data link anomaly Bureau bypass.
Inter agency extension. 10BASE-T.
For Q mode.
Control layer /MELSECNET/10 (H) is the middle layer of the whole network system,
Control network which is convenient and high speed processing data transmission between PLC, CNC and other control equipment.
As MELSEC control network MELSECNET/10,
With its good real-time performance, simple network settings, no procedures of the network data sharinng concept,
As well as the redundant circuit and so on, has obtained the very high market appraisal,
The number of devices to reach the highest in japan,
In the world is also one of the few AX80Y80C datasheet.
And MELSECNET/H not only inheritedd the excellent characteristics of MELSECNET/10,
Also makes the network real-time better, more data capacity,
Further adapt to the needs of the market AX80Y80C PDF datasheet .
Related products
MITSUBISHI
DC input / relay output module
AX80Y14CEU
MITSUBISHI DC input / relay output module AX80Y14CEU
Input points: 16 points. Input voltage a
MITSUBISHI
DC input / transistor output module
AX80Y80C
MITSUBISHI DC input / transistor output module AX80Y80C
Input points: 16 points. Input voltage a
MITSUBISHI
Input module
AX80
MITSUBISHI Input module AX80
Input points: 16 points. Voltage: DC12/2
MITSUBISHI
DC input / relay output module
AX80Y10C
MITSUBISHI DC input / relay output module AX80Y10C
Input points: 16 points. Input voltage a