Number of inputs: 8 pts.
Input Voltage: 200 to 240VAC.
Input Current: 6 mA.Model: CPM2A-20CDR-D. Power supply: DC power supply.
Output type: Relay.
Inputs points: 12 points.
Outputs points: 8 points.Type: CJ1 Special I/O Unit.
Name: CompoBus/S Master Unit.
Specifications: Communications functions,
Remote I/O communications; No OMRON CRT1B-OD02S-1 PDF catalog. of I/O points,
256 max. (128 inputs and 128 outputs);
Max
CRT1B-OD02S-1 Units mountable per CPU Unit: 40.
No. of unit numbers allocated: 1 or 2(variable).
Current consumption : 5V, 0.15A; 24V,--.
Standards: UC1, N, L, CE.
CompoBus/S is a high-speed I/O bus. Name: MIL Connectors.
Specifications: Outputs; 16 outputs ; PNP; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet OMRON CRT1B-OD02S-1 PDF catalog.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error OMRON CRT1B-OD02S-1 PDF catalog. I/O points: 256 pts.
Program capacity(words): 7.2 K.
DM capacity (words): 6 K.
RS-232C port: YES.
ABS interface: Yes.1 set (2 included).Name: I/O Control Unit.
Specifications: Applicable systems,
Duplex CPU, Single I/O Expansion System,
or Single CPU System;
Duplexing, Not supported;
Online Replacement, Not supported;
Mounting Backplane,CPU Backplane;
Connecting Cable,
Long-distance Connecting Cable.
Current consumption: 5V system, 0.92A;
26V system, --.
Standards: U, C, N, L, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables. Model: CPM2C-16EDM. Units with inputs only.
1 MIL connector.
Inputs: 16 inputs.
Outputs: ---.
Input type: 24 VDC.
Output type: --.Unit type: CJ1 Basic I/O Units.
name: B7A Interface Units.
Specifications: I/O points, 64 outputs;
External connection, Removable terminal block.
No. of words allocated: 4 words.
Current consumption: 5V, 0.07A; 24V, --.
Standards: UC1, CE.
It transmits 16 pooints of I/O signals per,
word with a pair of cables CRT1B-OD02S-1 PDF datasheet.
Easy and minimized wiring effort,
The B7A Interface Unit and B7A Link Terminal,
can be used in the same way as a standard,
Basic I/O Unit and I/O Terminal withoutt,
any need to worry about communications CRT1B-OD02S-1 PDF datasheet.
This characteristic reduces the wiring,
when using more than one relatively remote,
sensor or actuator.