Size: 96 x 96mm.
Type: Platinum resistance.
Adjustment mode: ON/OFF action or PID action.
Alarm: single alarm.
Output: relay output.
Temperature controller with single alarm output.
SV and PV can be displayed at the same time.
Multiple temperature range allows setting the optimum temperature range.
The protection function can prevent the error in operation E5CN-R1TU PDF catalog . Size: 96 x 96mm.
Control output 1: current
E5CN-R1TU
Auxiliary (alarm) output: 4.
Transfer output: have.
Event input: 4.
Communication: RS-485.
Disconnection detection: 2.
Power supply voltage: DC24V/AC24V.
E5 - C series of new products program.
Maximum 256 segment of the program capacity,
Support for multiple applications.
Can be set up to 8 procedures (mode) x 32 (step) procedure E5CN-R1TU PDF catalog .
The use of high 25mm (E5AC-T), 18mm (E5AC-T) PV display (white),
Improve visibility.
Not only on the top of the body, but also on the front,
The use of communication adapter cable (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CX-Thermo (sold separately).
High speed sampling to achieve 50ms E5CN-R1TU PDF catalog .
With auxiliary output (4 points), event input (maximum 6 points), the transmission output,
Support a variety of applications.
Slender fuselage depth 60mm.
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication OMRON E5CN-R1TU PDF datasheet.
Add position proportional control type, also support control valve control. E3JK-R42J regression reflection type,
E3JK communication mode: mode; ON,
Miniature amplifier built-in type photoelectric switchThe main body: terminal type, temperature input type OMRON E5CN-R1TU PDF datasheet.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling OMRON E5CN-R1TU PDF datasheet.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Furtherr performance improvement E5CN-R1TU datasheet.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivee display PV/SV E5CN-R1TU PDF catalog .
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.