LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Catalog Download >> A9GT-QC150BS
A9GT-QC150BS PDF catalog MITSUBISHI Q bus connecting cable A9GT-QC150BS datasheet PDF datasheet
Product model: A9GT-QC150BS
Name: Q bus connecting cable
Brand: MITSUBISHI
Sort: PDF datasheet
File language: English
Input type: AC/DC.
Input points: 16 points.
Input voltage: 12/DC24.
Input current: 4.2/8.6.
Connection mode: terminal row.
Common common point: 16.
The instruction list programming language is a programming language similar to assembly language mnemonic,
As well as assembly language by the operation code and the number of operations MITSUBISHI Q bus connecting cable PDF datasheet.
In the case of the computer for the PLC handheld programmer compile user program A9GT-QC150BS
At the same time, the programming language of the instruction list corresponds to the ladder diagram programming language,
In PLC programming software can be converted to each other. Figure 3 is the instruction sheet corresponding to the ladder diagram of figure 2PLC.
The characteristics of instruction table programming language is used to represent mnemonic operation function,
Easy to remember, easy to grasp;
In the handheld programmer on the keyboard using the mnemonic representation, easy to operate, can be programmed in computer;
There is a one-to-one correspondence between the ladder diagram and the ladder diagram MITSUBISHI Q bus connecting cable PDF datasheet. Its characteristics are basically consistent with the ladder diagram language MITSUBISHI Q bus connecting cable PDF datasheet. Output type: bidirectional thyristor output.
Output points: 16 points.
OFF leakage current: 1.5mA following (AC100V) below /3mA (AC200V).
Output protection function: No A9GT-QC150BS PDF datasheet.
Rated load voltage / current: AC100V~240V/0.6A.
External connection: 2 wire.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup A9GT-QC150BS PDF datasheet.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool. Applicable model: A95_GOT (-M3) A9GT-QC150BS PDF datasheet. Ontology CPU installation to P-ROM program device.Input points: 16 points.
Input voltage and current: 240V ~ 10mA AC100.
Input response time: 35ms.
16 point /1 a public side.
Output points: 12 points.
Output voltage: AC100 ~ 240V.
OFF leakage current: 3mA.
Output response time: 0.5Hz+1ms.
Output type: bidirectional thyristor output.
8 point /1 a public end, 4 points / a public end.
36 point terminal station.
With short circuit protection.
With the surge absorber.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan faullt signal A9GT-QC150BS PDF catalog.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drivee system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points MITSUBISHI Q bus connecting cable PDF datasheet.
Related products
MITSUBISHI
Bus connection unit
A9GT-QBUS2SU
MITSUBISHI Bus connection unit A9GT-QBUS2SU
QCPU Q mode us connection. 2 joint. A
MITSUBISHI
Memory card
A9GT-QFNB8M
MITSUBISHI Memory card A9GT-QFNB8M
Optional features of memory card Q/QnA/
MITSUBISHI
Memory card
A9GT-QFNB4M
MITSUBISHI Memory card A9GT-QFNB4M
Optional features of memory card Q/QnA/