Time specification: Inverse type.
Current setting range: 20 to 65 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage KS1-ANDC10 PDF catalog .
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase
KS1-ANDC10
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions KS1-ANDC10 PDF catalog . Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Appearance: surface type S5 shell.
Static type reverse electric relay K2WR type.
Reverse power relay for household and marine generator.
A high precision power detection can be performed by the analog time division multiplier KS1-ANDC10 PDF catalog .
Through the rated voltage of the switch, adjust the current simulation of variable,
Can correspond to the rated value of all generators.
Due to the instant start in contact, the response difference is minimal,
Position detection with high accuracy OMRON KS1-ANDC10 PDF datasheet. Sharing with voltage input, no need to control the power supply OMRON KS1-ANDC10 PDF datasheet.
Because it is static, so the anti vibration impact ability, action stability.
Equipped with easy to manage and maintain the boot display with LED. Time specification: Instantaneous type.
Current setting range: 8 to 26 A.
Operating voltage: 400/440 VAC.
Resetting method: Automatic (See note OMRON KS1-ANDC10 PDF datasheet. ).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated froom the start of operation KS1-ANDC10 datasheet.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions KS1-ANDC10 PDF catalog . Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.