Actuator: Plunger.
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 1NC/1NO (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC.
M12-connector models are available, saving on labor and,
simplifying replacement D4N-2A25 INSTRUCTION sheet.
Standardized gold-clad contacts provide high contact reliability
D4N-2A25
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. Ratings: Standard load; 5 A at 125 VAC.
Cable: VCTF oil-resistant cable *1.
Actuator: Roller plunger.
Cable length : 5 m.
Compact Limit Switch That''s Also D4N-2A25 INSTRUCTION sheet.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material D4N-2A25 INSTRUCTION sheet.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers OMRON D4N-2A25 Manual.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking OMRON D4N-2A25 Manual.
(Applicable only to standard models.)Actuator: Shaft.
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 1NC/1NO (Slow-action).
Compact, Plastic-body Safety-door.
Hinge Switch Designed for Saving.
Space in Machines and Other.
Equipment.
Lineup includes three contact models with 2NC/1NO and OMRON D4N-2A25 Manual.
3NC contact forms in addition to the previous contact forms.
1NC/1NO, and 2NC. Models with MBB contacts are also available.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads. Actuator: Roller lever (Metal lever, resin roller).
Cable length: 1 m.
Pull-outing direction of cable: Horizontal.
Built-in switch: 2NC (slow-action).
Smallest Class of Safety Limit Switchess the World D4N-2A25 .
The world''s smallest limit switch with a direct opening,
mechanism (four-contact construction model).
High-sensitivity safety limit switch.
Built-in switches with two- or four-contact construction are avaailable D4N-2A25 INSTRUCTION sheet.
Degree of protection: IP67.
Conforms to EN115-1, EN81-1 and EN81-2.
(slow-action models only).
Certified standards: UL, EN (TÜV), and CCC.