Manual Download >> D4N-2C2HR
pull-reset safety limit switch D4N-2C2HR Manual OMRON D4N-2C2HR INSTRUCTION sheet
Product model: D4N-2C2HR
Name: pull-reset safety limit switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Release Key Type: Standard (metal).
Wiring method: Connector.
Solenoid voltage/Indicator: 24VDC (without indicator).
Lock and release type: Mechanical lock Solenoid release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 4-contact Model,
Insert the built-in switch (A, B, C, D, S, T, U or V) into the blank @ D4N-2C2HR Manual.
Conduit size (See Note D4N-2C2HR): M20.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available) D4N-2C2HR Manual.
Key holding force of 1,300 N.
It is possible to change the key insertion point.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames D4N-2C2HR Manual.
The plastic material makes the Slide Key suitable,
for lightweight doors. Specifications: Outputs; PNP (+ common); 8 points.
I/O connections: M3 Screw terminals.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC OMRON D4N-2C2HR INSTRUCTION sheet.
Allows I/O Expansion with Transistor Terminals.
Wide variety of data, such as maintenance system data,
can be collected without affecting the productivity,
of the control system OMRON D4N-2C2HR INSTRUCTION sheet.
Valuable information can be collected,
and managed through the network, including information,
on the communications power supply.
voltage levels, Unit wear and tear,
and equipment operating information.
Expansion via Expansion I/O Units OMRON D4N-2C2HR INSTRUCTION sheet.
With no communications baud rate settings,
required and detachable terminal blocks,
maintenance is easier. Actuator: Roller plunger.
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 2NC/1NO MBB (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact foorms D4N-2C2HR .
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used witth both standard loads and microloads D4N-2C2HR Manual.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC.
Related products
OMRON
Safety Limit Switch
D4N-1E62
OMRON Safety Limit Switch D4N-1E62
Actuator: One-way roller arm lever hori
OMRON
Safety Limit Switch
D4N-2B87
OMRON Safety Limit Switch D4N-2B87
Actuator: Plastic rod. Conduit size: 1-
OMRON
Safety Limit Switch
D4N-1E31
OMRON Safety Limit Switch D4N-1E31
Actuator: Plunger. Conduit size: 1-cond
OMRON
Safety Limit Switch
D4N-2BRE
OMRON Safety Limit Switch D4N-2BRE
Actuator: Fork lever lock right operati