Terminal type: Exposed-lead Models.
Protective tubing diameter D: 3.2 dia.
Protective tubing length L: 35cm.
Lead wire type: Heat resistive.
Lead wire length M: 2m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E2V-X8C2 Manual.
Ideal for the thermal input devices of Temperature Controllers
E2V-X8C2
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: M8(Stainless steel)(See note 2.); Single; Unshielded.
Sensing distance: 2 mm.
Connecting method (See note 1 E2V-X8C2 Manual. ): Pre-wired.
Body length: Long.
Output configuration: NPN.
Operation mode NC.
A new generation in global applications. E32-A08 type: special beam type; liquid level detection,
Specialty: the detection range of the detection location is scattered less than 0.2mm,
Bending radius (mm): R25.
Fiber element for meeting diversified needsAppearance: Shielded, M30.
Sensing distance: 15 mm E2V-X8C2 Manual.
Output: NPN.
Model: Operation mode NC.
Aluminum and Iron Both.
Detectable from Long Distances. Size: 48 x 48mm.
Body: terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: relay output.
Control mode: standard or heating cooling OMRON E2V-X8C2 INSTRUCTION sheet.
Auxiliary output points: 2 points.
The failure detection function of the heater with the broken line and SSR: - OMRON E2V-X8C2 INSTRUCTION sheet.
Event input points: -.
Transfer output: -.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance OMRON E2V-X8C2 INSTRUCTION sheet.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensorss E2V-X8C2 .
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to eexecute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault