Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function E2E-C03SR8-CJ-C2 INSTRUCTION sheet
E2E-C03SR8-CJ-C2
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance E2E-C03SR8-CJ-C2 INSTRUCTION sheet.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc E2E-C03SR8-CJ-C2 INSTRUCTION sheet. , can be a key operation. Size: DIN 1/16, 48 X 48 x 60mm.
Power supply voltage: AC100 ~ 240V.
Input type: Platinum resistance.
Alarm points: -.
Control output: voltage output (for driving SSR) OMRON E2E-C03SR8-CJ-C2 Manual.
Simple new temperature controller, easy to achieve temperature control.
Good visibility (character height E5CSL:21 OMRON E2E-C03SR8-CJ-C2 Manual. 7mm, E5CWL:16.2mm (PV), E5EWL:20mm (PV)).
From the front panel depth: 60mm.
Parameter is less, set simple.
Sampling time was reduced to 250ms. Gradient Temperature Control to Achieve.
Consistent Layer Temperature.
Perform gradient temperature control ranging from 2 to 32,
channels OMRON E2E-C03SR8-CJ-C2 Manual.
Perform 2-channel gradient temperature control for up to 16,
groups, or 32-channel gradient temperature control for up to 2,
groups.
Set gradient temperature control or 2-PID control for each,
group E2E-C03SR8-CJ-C2 .
Reduce design work for ladder programming with programless,
connections to Programmable Controllers. (The same feature,
as Standard-control EJJ1 Models E2E-C03SR8-CJ-C2 INSTRUCTION sheet. ).
Connect directly to the G3ZA Multi-channel Power Controller,
using optimum cycle control for high-accuracy control with,
minimal noise.