LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> E3ZM-D67
photoelectric sensors E3ZM-D67 INSTRUCTION sheet OMRON E3ZM-D67 Manual
Product model: E3ZM-D67
Name: photoelectric sensors
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 3.2 dia.
Protective tubing length L: 15 cm.
Lead wire type: Heat resistive.
Lead wire length M: 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E3ZM-D67 INSTRUCTION sheet.
Ideal for the thermal input devices of Temperature Controllers E3ZM-D67
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. E32-T14L type: standard type; standard,
Specialty: 3 cylinder side,
Shape / detection distance (mm): 600; 460; 300 (120),
Bending radius (mm): R25 E3ZM-D67 INSTRUCTION sheet.
Standard test object (minimum test object) (mm) 1: 1 (0.005),
Fiber element for meeting diversified needsProtective tubing length (mm): W1/4 screw.
Lead wire length: 4 m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers E3ZM-D67 INSTRUCTION sheet.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal OMRON E3ZM-D67 Manual. Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode OMRON E3ZM-D67 Manual.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input OMRON E3ZM-D67 Manual.
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes thhe process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E3ZM-D67 .
Through the infrared port can be carried out from the frront of the communication E3ZM-D67 INSTRUCTION sheet.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
Related products
OMRON
Compact Photoelectric Sensor
E3ZM-LS61H
OMRON Compact Photoelectric Sensor  E3ZM-LS61H
Sensing method: BGS reflective fixed di
OMRON
Compact Photoelectric Sensor
E3ZM-LS69H
OMRON Compact Photoelectric Sensor  E3ZM-LS69H
Sensing method: BGS reflective fixed di
OMRON
Compact Photoelectric Sensor
E3ZM-LS84H
OMRON Compact Photoelectric Sensor  E3ZM-LS84H
Sensing method: BGS reflective fixed di
OMRON
Compact Photoelectric Sensor
E3ZM-R66
OMRON Compact Photoelectric Sensor  E3ZM-R66
Sensing method: Retro reflective wit MSR