LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> D4SL-N2DFA
guard lock safety-door switch D4SL-N2DFA Manual OMRON D4SL-N2DFA INSTRUCTION sheet
Product model: D4SL-N2DFA
Name: guard lock safety-door switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
Actuator: Roller lever (resin lever, resin roller).
Conduit size: 2-conduit; M20.
Built-in switch mechanism: 1NC/1NO(Snap-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms D4SL-N2DFA Manual.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement D4SL-N2DFA
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. The type of the drive lever: one way action roller rocker type (horizontal action) D4SL-N2DFA Manual.
Conduit size: single catheter type, M20.
Built in switch structure: slow motion (1NC/1NO).
Safety limit switch in accordance with global standard EN 50047.
The contact constitutes a complete variety, there is a single point of specification (1NC) and double contact specifications (1NC/1NO, 2NC).
Forced open action structure D4SL-N2DFA Manual.
The slow moving contact structure is adopted to ensure that the contact distance is 4mm.
Elevator and escalator can be used. Actuator: Roller plunger.
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 1NC/1NO(Snap-action).
Popular Safety Limit Switches OMRON D4SL-N2DFA INSTRUCTION sheet.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms OMRON D4SL-N2DFA INSTRUCTION sheet.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only) OMRON D4SL-N2DFA INSTRUCTION sheet.
Certified standards: UL, EN (TÜV), and CCC. Release Key Type: Standard (metal).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (without indicator).
Lock and release type: Solenoid lock Mechanical release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 4-contact Model,
Insert the built-in switch (A, B, C, D, S, T, U or V) into the blank @.
Conduit size (See Note.): G1/2.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key inseertion point D4SL-N2DFA .
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lockk Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames D4SL-N2DFA Manual.
The plastic material makes the Slide Key suitable,
for lightweight doors.