Receptacle box: G 1/2 Conduit.
Indicator: With LED indicator (DC).
Actuator: Flexible rod, Spring wire.
The Limit Switch with Better Seal,
Shock Resistance, and Strength.
A double seal on the head, a complete gasket cover, and,
other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13) D4NL-4HFG-B4-NPT Manual.
Wide standard operating temperature range:
-40°C to +100°C (standard type)
D4NL-4HFG-B4-NPT
Models with fluoro-rubber available for greater resistance to chemicals.
Block mounting method also reduces downtime for maintenance.
DPDT, double-break models available for complex operations.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved model.) Ratings: Standard load; 5 A at 250 VAC, 4 A at 30 VDC D4NL-4HFG-B4-NPT Manual.
Cable: SJT(O) cable *3.
Actuator: Sealed roller plunger.
Cable length : 5 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material D4NL-4HFG-B4-NPT Manual.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables OMRON D4NL-4HFG-B4-NPT INSTRUCTION sheet.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation OMRON D4NL-4HFG-B4-NPT INSTRUCTION sheet.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Head material: Plastic*1.
Release key position: Bottom.
Release key type: Standard (resin).
Solenoid voltage/indicator: Solenoid: 24 VDC, Orange LED: 10 to 115 VAC/VDC OMRON D4NL-4HFG-B4-NPT INSTRUCTION sheet.
Lock and release types: Mechanical lock Solenoid release.
Contact configuration(door open/closed detection switch and,
lockmonitor switch contacts)(slow-action) Certified direct,
opening NC contact: 2NC+1NC/1NO.
Conduit opening: M20.
Best-selling Guard Lock Safety-door.
Switch Available in Several.
Compact, Multi-contact Models.
Selectablle Operation Key insertion direction and,
adjustable mounting ensure installation flexibility D4NL-4HFG-B4-NPT .
Built-in switches with multiple-contact construction are available.
Key holding force of 1,300 N minimum.
Can be used for eithher standard loads or microloads D4NL-4HFG-B4-NPT Manual.
Lineup includes models with a conduit size of M20.
IP67 degree of protection.