The main body: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: relay output.
Control output 2: voltage output (SSR driver)
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function E5EC-CX4ASM-013 Manual
E5EC-CX4ASM-013
Event input points: -.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement E5EC-CX4ASM-013 Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Size: 48 x 48mm.
Control output 1: voltage E5EC-CX4ASM-013 Manual.
Auxiliary (alarm) output: 3.
Transfer output: -.
Event input: -.
Communication: -.
Break detection: -.
Power supply voltage: DC24V/AC24V.
The white PV (current value) with excellent visibility shows the segment to make the confirmation work more easily OMRON E5EC-CX4ASM-013 INSTRUCTION Manual.
Eye-catching white + industry''s largest display size
The black and white display and the industry''s largest display size to achieve excellent visibility OMRON E5EC-CX4ASM-013 INSTRUCTION Manual.
No matter from which angle or in the natural lighting environment, the dark scene,
Can quickly and accurately confirm the current value.
Displays the current value (PV/ white), the target value (SV/ green) and the progress of the program (PRG, SEG/ yellow) OMRON E5EC-CX4ASM-013 INSTRUCTION Manual.
Can be viewed at the same time, there is no need to switch the display, so as to improve the efficiency of operations. Size: 96 x 96mm.
Control output 1: relay.
Auxiliary (alarm) output: 4.
Transfer output: -.
Event input: 2.
Communication: RS-485.
Disconnection detection: 1.
Power supply voltage: AC100 ~ 240V.
E5 - C series of new products program.
Maximum 256 segment of the program capacity,
Support for multiple applications.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
The use of high 25mm (E5AC-T), 18mm (E5AC-T) PV display (white),
Improve visibility.
Not only on the top of the body, but also on the front,
The use of communication adapter cable (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CX-Thermo (sold separately).
High speed sampling to achhieve 50ms E5EC-CX4ASM-013 .
With auxiliary output (4 points), event input (maximum 6 points), the transmission output,
Support a variety of applications.
Slender fuselage depth 60mm.
Easy to connect with PLC through no program communicatiion E5EC-CX4ASM-013 Manual.
Combined temperature control device through component communication.
Add position proportional control type, also support control valve control.