Size: 1/16 DIN 48 × 48 × 78 (W × H × D).
Power supply voltage: 100 to 240 VAC.
Input type: Analog (current/voltage).
Alarm output: 2.
option units Mounting: Yes.
Control output: Relay output.
Previous mode: None.
This Best-selling General-purpose,
48×48-mm Temperature Controller,
Is Now Even Better E5EC-CX2DSM-800 Manual.
Controllers now available with analog inputs.
Faster sampling at 250 ms
E5EC-CX2DSM-800
Transfer output provided for easy output to recorders.
Models available with a loop break alarm (LBA) and,
heater short alarm (HS alarm).
Easy setting with 11-segment displays.
Setting protection indicator informs operator when,
protection is enabled.
Manual output provided.
New protocol called Modbus is installed in the models,
with communications E5EC-CX2DSM-800 Manual.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33. The main body: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: current output.
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points E5EC-CX2DSM-800 Manual.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function.
Event input points: -.
Transfer output: output (using control output).
Communication: - OMRON E5EC-CX2DSM-800 INSTRUCTION Manual.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement OMRON E5EC-CX2DSM-800 INSTRUCTION Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV OMRON E5EC-CX2DSM-800 INSTRUCTION Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-422.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makees the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E5EC-CX2DSM-800 .
Through the infrared port can be carried out from the frront of the communication E5EC-CX2DSM-800 Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.