Sensing method: Retro reflective.
Appearance: Horizontal.
Connection method: Standard M12 Connector.
Sensing distance: 1m [100 mm].
Model: PNP output.
Recommended application: Flat object,
Detecting glass wafers and LCD glass circuit boards, Ideal;
Cylindrical object,
Detecting plastic bottles and other transparent containers, -- E5EN-HSS2HH01BD-FLK User's Manual.
Ideal for Detecting Glass Wafers,
and Other Transparent Objects,
Detects glass wafers and LCD glass circuit boards
E5EN-HSS2HH01BD-FLK High performance price ratio standard type proximity sensor.
Standard cable protector.
The new DC two-wire type.
Non polar proximity sensor.
Type: DC / wire type.
Polarity: there.
Shape: shield, M30.
Detection range: 10mm.
Action mode: NO. Size: 48 x 48mm E5EN-HSS2HH01BD-FLK User's Manual.
Control output 1: current.
Auxiliary (alarm) output: 3.
Transfer output: -.
Event input: 2.
Communication: RS-485.
Disconnection detection: 1.
Power supply voltage: DC24V/AC24V.
The white PV (current value) with excellent visibility shows the segment to make the confirmation work more easily.
Eye-catching white + industry''s largest display size
The black and white display and the industry''s largest display size to achieve excellent visibility E5EN-HSS2HH01BD-FLK User's Manual.
No matter from which angle or in the natural lighting environment, the dark scene,
Can quickly and accurately confirm the current value.
Displays the current value (PV/ white), the target value (SV/ green) and the progress of the program (PRG, SEG/ yellow) OMRON E5EN-HSS2HH01BD-FLK MANUAL.
Can be viewed at the same time, there is no need to switch the display, so as to improve the efficiency of operations OMRON E5EN-HSS2HH01BD-FLK MANUAL. The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: current output.
Control mode: standard.
Auxiliary output points: - OMRON E5EN-HSS2HH01BD-FLK MANUAL.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performancce improvement E5EN-HSS2HH01BD-FLK Communications Functions.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivee display PV/SV E5EN-HSS2HH01BD-FLK User's Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.