Appearance: M30.
Sensing distance: 20 mm.
Connection method: M12 Pre-wired Smartclick Connector Models(0.3m).
Cable specifications: PVC (oil-resistant).
Polarity: Yes.
Operation mode : NO .
Pin arrangement: 1: +V, 4: 0 V.
Applicable connector code: G.
Your Search for Proximity Sensors.
Starts with the World-leading E5AN-HTAA2HBMD-500 MANUAL.
Performance and Quality of the E2E.
Standard Sensors for detecting ferrous metals
E5AN-HTAA2HBMD-500
Wide array of variations. Ideal for a variety of applications.
Models with different frequencies are also available to prevent,
mutual interference.
Superior environment resistance with standard cable made of oil,
resistant PVC and sensing surface made of material that resists,
cutting oil E5AN-HTAA2HBMD-500 MANUAL.
Useful to help prevent disconnection.
Cable protector provided as a standard feature. Size: M8(Stainless steel)(See note 2.); Double; Unshielded.
Sensing distance: 4 mm.
Connecting method (See note 1.): M8 Connector (3-pin).
Body length: Short.
Output configuration: NPN.
Operation mode NO.
A new generation in global applications. Size: 48 * 48mm, terminal type.
Type: control output 1 point type (power AC/DC24V) E5AN-HTAA2HBMD-500 MANUAL.
Shell color: black.
Control output: linear voltage output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -.
Event entry point: 2.
Transfer output: output (special terminal) OMRON E5AN-HTAA2HBMD-500 User's Manual.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved OMRON E5AN-HTAA2HBMD-500 User's Manual.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors OMRON E5AN-HTAA2HBMD-500 User's Manual.
Add PV/SV state display function, to see the state of the thhermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV E5AN-HTAA2HBMD-500 Communications Functions.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can performm flexible contact output E5AN-HTAA2HBMD-500 MANUAL.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.