LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> FX3UC-4AD
Special unit FX3UC-4AD INSTALLATION MANUAL MITSUBISHI FX3UC-4AD Manual
Product model: FX3UC-4AD
Name: Special unit
Brand: MITSUBISHI
Sort: INSTALLATION MANUAL
File language: English
RS-485 communication adapter.
(need FX1N-8AV-BD).
(FX1S and FX1N host general). MITSUBISHI inverter series: FR-A820.
Voltage level: three phase 200V.
Power: 2.2kw.
SLD converter rated current: 16.7A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Parameters can be selected by 4 different rated current and different overload rating (SLD (ultra light load) rated, LD (light load) rating, ND (general load) rating, HD (weight) FX3UC-4AD INSTALLATION MANUAL FX3UC-4AD
Type load) for selection.
You can choose the most suitable frequency converter for use; and by selecting a transducer with a SLD or LD rated level,
Be able to reduce the size of the device (compared with the FR-A700 series, to reduce the volume of equipment) FX3UC-4AD INSTALLATION MANUAL.
For applications that require high torque at low speeds, the HD rating is the most suitable.
The controller is used to control and monitor the frequency converter through the network.
Standard corresponding RS-485 communication (MITSUBISHI converter protocol, Modbus-RTU protocol) data transmission speed up to 115200bps. MITSUBISHI inverter series: FR-A820.
Voltage level: three phase 200V FX3UC-4AD INSTALLATION MANUAL.
Power: 45kw.
SLD converter rated current: 233A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Parameters can be selected by 4 different rated current and different overload rating (SLD (ultra light load) rated, LD (light load) rating, ND (general load) rating, HD (weight) MITSUBISHI FX3UC-4AD Manual.
Type load) for selection.
You can choose the most suitable frequency converter for use; and by selecting a transducer with a SLD or LD rated level,
Be able to reduce the size of the device (compared with the FR-A700 series, to reduce the volume of equipment) MITSUBISHI FX3UC-4AD Manual.
For applications that require high torque at low speeds, the HD rating is the most suitable MITSUBISHI FX3UC-4AD Manual.
The controller is used to control and monitor the frequency converter through the network.
Standard corresponding RS-485 communication (MITSUBISHI converter protocol, Modbus-RTU protocol) data transmission speed up to 115200bps. MITSUBISHI inverter FR-E720 series.
Voltage level: 3 phase 200V.
Frequency converter capacity: 0.75KW.
In order to ensure the reliability of production, all production machinery in the design of power with drive, there is a certain amount of surplus.
When the motor can not run under full load, in addition to meet the requirements of power driven,
The surplus torque increases the active power consumption, resulting in the waste of electric energy.
Speed control method of fan and pump equipment trraditional by regulating the entrance or exit of the baffle, valve opening to regulate air flow and water flow
, the input power is large, and a large amount of energy consumption in the baffle, the valve in the processs of closure FX3UC-4AD INSTALLATION MANUAL FX3UC-4AD .
When using variable frequency control, if the flow rate is reduced, the speed of the pump or fan can be reduced to meet the requirements.
Related products
MITSUBISHI
RS-232 communication
FX3U-232ADP-MB
MITSUBISHI RS-232 communication FX3U-232ADP-MB
RS-232 communication. Special communicat
MITSUBISHI
PLC
FX3UC-32MT/DSS
MITSUBISHI PLC FX3UC-32MT/DSS
Input and output points: 32 points. Inpu
MITSUBISHI
Display module
FX3U-7DM-HLD
MITSUBISHI Display module FX3U-7DM-HLD
Can monitor and change the value of the