LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> FX2N-232IF
RS232C INTERFACE BLOCK FX2N-232IF HARDWARE MANUAL MITSUBISHI FX2N-232IF Manual
Product model: FX2N-232IF
Name: RS232C INTERFACE BLOCK
Brand: MITSUBISHI
Sort: HARDWARE MANUAL
File language: English
Convert connectors to fast connectors.
According to the location of the connection equipment distribution module. MITSUBISHI inverter series: FR-F840.
Voltage level: three phase 400V.
Power: 3.7kw.
SLD converter rated current: 8.3A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have FX2N-232IF HARDWARE MANUAL.
2 times the power consumption of the wind turbine and pump and the speed of the 3 power consumption is proportional to the speed of the rotating speed FX2N-232IF
Through the speed control of the frequency converter to adjust the air flow, can reduce the power consumption.
Give full play to the performance of the motor.
The excitation current is always adjusted to the best state, which can improve the efficiency of the motor FX2N-232IF HARDWARE MANUAL.
Load torque is smaller, can further improve energy efficiency.
For example, when a general motor is used, the optimal excitation control mode in the 4% motor load torque is about 30% more than that of the V/F control. Length: 1 meters.
Operation panel or parameter unit connection line. Power: 1.5kw.
Purpose: high frequency braking resistor.
The use rate of the built-in regenerative brake of the transducer can be promoted FX2N-232IF HARDWARE MANUAL.
When using the FR-ABR type brake resistor, the short circuit piece between the terminal PR-PX is removed. Does not remove the short circuit chip will lead to overheating of the brake resistor MITSUBISHI FX2N-232IF Manual.
The utilization rate of the regenerative braking should be less than the allowable brake use rate in the above table.
With the operating frequency of the brake resistor to reach 300 degrees C or higher, it is necessary to take protective measures and cooling MITSUBISHI FX2N-232IF Manual.
MYS type resistor can be used. But please pay attention to the allowable brake use rate.
Do not remove the terminal P/+ and P1 between the short circuit chip, in addition to connecting the DC reactor MITSUBISHI FX2N-232IF Manual.
The installation of thermal relay, to avoid overheating and burn the braking resistor. Max input / output points: 128 points.
Power supply voltage: DC24V.
Input points: 64 points.
Output points: 64 points.
Output type: relay.
Power consumption: 100VA.
Weight (kg):1.8.
Size (WxHxD) mm:350x90x87.
Since the FX2n series have the following features: the maximum range of inclusive of the standard features, program execution faster, the full complement of communication function, suitable for different countries in the world, and the power to meet a large number of special function modules of individual needs,
It can provide maximum flexibility and control capability for your factory automation applications.
Control 16~256 point.
Built in 8K capacity of the RAM memory, the maximum can be extended to 16K.
CPU arithmetic processing speed of 0.08 S/ basic instructions.
On the right side of the FX2N serries can be connected to the input and output expansion modules and special function modules FX2N-232IF .
The basic unit is built in the 2 axis independent maximum 20kHz positioning function (transistor output type).
Quick disconnect the terminal block, which adopts excellent maintainability to quickly disconnect the terminal blocks, even if the cable is then replaced by the cable FX2N-232IF HARDWARE MANUAL.
Related products
MITSUBISHI
Input / output module
FX2N-48ET-DSS
MITSUBISHI Input / output module FX2N-48ET-DSS
Input and output points: 48 points. DC p
MITSUBISHI
PLC
FX2N-32MT-D
MITSUBISHI PLC FX2N-32MT-D
Max input / output points: 32 points. Po
MITSUBISHI
PLC
FX2N-64MT-ES/UL
MITSUBISHI PLC FX2N-64MT-ES/UL
Max input / output points: 64 points. Su
MITSUBISHI
Master station module for CC-Link
FX2N-16CCL-M
MITSUBISHI Master station module for CC-Link FX2N-16CCL-M
Master station module for CC-Link. FX2N-