Operation control mode: stored procedure repeated operation.
Input / output points: 4096 points.
Program capacity: 80K.
Newly developed high speed parallel control execution engine and high speed system bus
In the large and complex production system, it is necessary to shorten the time of production REGISTRO ITALLANO NAVALE.
IQ-R MELSEC series of new development of the basic operation processing speed (LD instructions) for the 0
REGISTRO ITALLANO NAVALE98ns ultra high speed processing and control execution engine,
And the high speed system bus which can significantly improve the communication between the multi CPU and the data communication speed between the network module and the network module,
Helps to shorten the production cycle of the production system REGISTRO ITALLANO NAVALE.
Program capacity of up to 1200K.
Multi CPU system for high precision motion control.
The built-in CPU module support 2 Gigabit Network port.
Database functions to facilitate data management.
Extended SRAM card with built-in security function.
Can be carried out a variety of motion control (position, speed, torque, advanced synchronous control, etc.).
In line with the international safety standards (13849-1 PL e ISO, IEC 61508 SIL 3) security CPU REGISTRO ITALLANO NAVALE.
The most suitable for C/C++ language programming from the computer / computer environment for transplantation. Output points: 16 points.
Output form: relay output.
Rated open and close voltage, current: DC24V/2A, AC240V/2A.
Rated load voltage.
Max load current: -.
Response time: 12ms.
Common way: 16 point / public end.
Protection function (overload, overheat).
External wiring connection mode: 18 point screw terminal.
Output module with mechanical relay contact mechanism,
Including the load voltage range of the relay and can be used for the output of the DC12~24V load transistor output type.
According to the load voltage, the output points of different, choose the most suitable user needs of the module.
Preventive maintenance based on the life of relay contact.
Relay output module can accumulate the number of ON of each output point.
Through the understanding of the relay contacts of the number of times, according to the relay life of preventive maintenance. "Input points: 16 points.
Rated input voltage, frequency: AC100 ~ 120V, 50/60Hz.
Rated input current: 8.2mA (AC100V, 60Hz), 6.8mA (AC100V, 50Hz).
Response time: 20ms.
Common way: 16 point / public end.
Interrupt function: have.
External wiring connection mode: 18 point screw terminal.
The input and output module is the interface between the switch, sensor, actuator, and other control system of the ON/OFF signal processing.
Compared with the previous series, iQ-R MELSEC series of input and output modules have more features,
1 modules can be used for a variety of purposes, to help reduce the cost of deployment and maintenance costs.
The module design of the pursuit of convenience".
Paste the white label on the input module and paste the red label on the output module,
The rated specifications are clearly marked on the front of the module, which can prevent the use of errors.
The input and output number stamped on the top of the front display input and output module LED, can easily connfirm the status of the ON/OFF REGISTRO ITALLANO NAVALE.
The terminal arrangement of each signal is recorded on the wiring terminal of the 16 point module, and the false wiring can be prevented.
The 64 point module can be 32 points as the unit, throough the switch to switch to display the input and output number REGISTRO ITALLANO NAVALE.
In addition, serial number tag in the front of the module, can be easily recognized. "