QS90SR2SP-Q Manual MITSUBISHI QS90SR2SP-Q User's Manual
Product model: QS90SR2SP-Q
Name: Safety Relay Module
Brand: MITSUBISHI
Sort: User's Manual
File language: English
Manual pulse generator /INC synchronous encoder input:
Use number: 3 sets of /1 modules.
Better user experience data recording function.
Easy to record, no need to program.
Simply through the special configuration tool wizard to easily complete the settings,
The collected data can be saved in CSV format to SD storage card MITSUBISHI QS90SR2SP-Q User's Manual.
Can be effectively used to save the CSV file to facilitate the creation of a variety of reference materials,
Including daily reports, generate reports and general reports QS90SR2SP-Q
These data can be applied to the data analysis, tracing, etc..
To record the change of control data without missing.
Data can be collected in a time interval or in a millisecond time interval,
To record the change of the specified control data without any omission MITSUBISHI QS90SR2SP-Q User's Manual.
Therefore, in the event of failure, can quickly determine the cause, the precise action analysis.Input: 2 channels.
10kpps.
Counter input signal: DC5/12/24V.
External input: DC5/12/24V.
Uniform output: Transistor (drain type).
Used to replace the A series of large modules "AD61-S1".
40 pin connector.
Support high resolution devices MITSUBISHI QS90SR2SP-Q User's Manual. Pulse input and high speed counter module product group satisfying high speed and high precision control application.
High speed counter module for counting high-speed pulse train.
Can be used in combination with the external encoder for positioning and other control.
The maximum count rate can be switched, and the low frequency pulse is counted from the high speed pulse to the rising edge / falling edge.
Each 1 channel is equipped with 2 points of external uniform output.
Can be selected according to the use of "consistent output function", "continuous comparison function", to achieve high-speed control of external equipment. (QD64D2)
Provides a variety of functions, such as the same output test function (using a continuous comparison function), the default function, the latch counter ffunction,
In order to meet the needs of various applications QS90SR2SP-Q Manual. (QD64D2)
The maximum count rate of the input pulse can be up to 8Mpps (differential input, 2 phase, 4 double frequency).
Can be in the semiconductor, liquid crystal mannufacturing and other high position accuracy requirements of the equipment,
Perform accurate position tracking using high resolution encoders QS90SR2SP-Q Manual. (QD65PD2)
Related products
MITSUBISHI
Safety relay module
QS90SR2SN-CC
MITSUBISHI Safety relay module QS90SR2SN-CC
Meet safety standards: EN954-1 class 4,
MITSUBISHI
Safety relay module
QS90SR2SP-EX
MITSUBISHI Safety relay module QS90SR2SP-EX
Application: extension. Suitale for saf
MITSUBISHI
Safety relay module
QS90SR2SP-Q
MITSUBISHI Safety relay module QS90SR2SP-Q
Application: Q series. Suitale for safe
MITSUBISHI
Safety relay module
QS90SR2SN-Q
MITSUBISHI Safety relay module QS90SR2SN-Q
Application: Q series. Suitale for safe