High performance type CPU, process CPU, memory card protection cover for redundant CPU.
Q3MEM-4MBS-SET bundled products.Input / output points: 4096 points.
You can use the CF card.
Version OS:VxWorks 5.4.
Easy connection programming tool via ethernet.
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings MITSUBISHI QS001CPU User's Manual
QS001CPU And there is no need to select the cable, the straight line and the cross line can be used.
Therefore, this connection method and the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection.
Easy connection through the hub CPU.
By using an Ethernet hub, programming tools and multiple CPU can be connected simultaneously MITSUBISHI QS001CPU User's Manual.
Through the programming tool can be searched and displayed in the list has been connected to the CPU.
Therefore, even if the IP CPU address is unknown, just choose from this list, you can easily connect.
Seamless communication without network level constraints.
With the latest high-speed, large capacity IE CC-Link controller network and IE CC-Link field network,
Corresponding to the increasing amount of information MITSUBISHI QS001CPU User's Manual.
Together with previous MELSECNET/H, Ethernet and CC-Link,
These networks can be across the network type or level of differences, to achieve seamless communication.
Programmable logic controller on the network through the programming tool of the Ethernet connection,
Monitoring and programming.Bidirectional thyristor output: 32 points.
Rated current and voltage: 240V ~ 0.6A/1 AC100 point, 2.4A/1 public end, 8 point 1 Public end.
Response time: 1ms+0.5 cycle.
External wiring connections: 38 terminals (terminals sold separately).
Replacement model: AY23."4 axes, SSCNET III type.
2 axis /4 axis /3 axis linear interpolation.
2 axis interpolation.
Control unit: mm, inch, degree, pulse.
Location data: 600 data / axis.
40 pin connector.
Through the SSCNET III cable connection to save wiring, the distance between the station up to 50m.
Absolute position system for determining the origin position is supported by the return data set operation.
In addition, the limit switch of the upper limit, the lower limit switch and the near point block signal input can be directly connected to the servo amplifier,
Thus greatly reducing the wiring requirements.
Eaasy to achieve high speed, high precision positioning control QS001CPU Manual.
Support for multiple types of positioning control,
Including 2 ~ 4 axis 2 axis linear interpolation, circular interpolation, speed control and speed / position control, ppath switching control, constant speed control etc QS001CPU Manual. .
In addition, can use the "Configurator-QP GX" and other software,
Easy to set, monitor and debug. "