Input: 4 channels.
Thermocouple (K, J, T, B, S, E, R, N, U, L, PLlI, W5Re/W26Re,,).
No heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal station.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost MITSUBISHI Q64AD2DA User's Manual.
Heating function at the same time
Q64AD2DA
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process.
Automatic adjustment of cost (time, material and electrical energy) can be reduced MITSUBISHI Q64AD2DA User's Manual.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode MITSUBISHI Q64AD2DA User's Manual.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected. Conversion of series Q shell, Q series I/O slot used for installation.Three-phase 4 wire type.
Measuring circuit number: 1 circuits.
Measurement items: power consumption (consumption, regeneration), current, voltage, power, power factor, etc..
Power measurement module product group capable of simply measuring various energy information.
With only one module can be used to measure and power consumption (consumption and regeneration), reactive power, current, voltage, power, power factor and frequency of all kinds of detailed information.
No ladder program can continue to monitor the minimum and maximum values, can also perform 2 types of upper / lower limit alarm.
Only in the ON state can be used to measure the output of the output device.
Therefore, the amount of electricity and the quantity of electricity in the unit of the beat can be obtained during the operation of the equipment.
3 phase 3 wire products can be used tto measure up to 4 circuits in one slot,
3 phase 4 wire products can be used to measure up to 3 circuits,
So the electrical energy measurement can be carried out in a small space by the multi circuit products Q64AD2DA Manual.
For example, a module ccan be used to measure other loads from the control panel trunk Q64AD2DA Manual.
In addition, Works2 GX (version 1.90U and higher) can be used to easily set parameters.