Q3MEM-4MBS Manual MITSUBISHI Q3MEM-4MBS Instruction manual
Product model: Q3MEM-4MBS
Name: Memory card
Brand: MITSUBISHI
Sort: Instruction manual
File language: English
Battery replacement.
Initial voltage 3.0V.
Base of large capacity battery.
Current capacity: 5000mAh.
Service life: 5 years.PCI bus /PCI-X bus.
Support Japanese, English OS.
Multimode fiber optic cable.
Dual loop controller network (control station / common station).
DB A20 AnyWire system uses a separate transmission mode,
Sensor networks to achieve high speed and high reliability MITSUBISHI Q3MEM-4MBS Instruction manual Q3MEM-4MBS
The transmission distance of 50m/200m/1km/3km can be selected.
1 modules can be up to 512 points of the input, 512 points of output (standard setting).
Even branch wiring, but also to detect transmission lines.
Province distribution network module in cabinet and device.
Link to connect the 64 stations when the fastest scanning time for 1 MITSUBISHI Q3MEM-4MBS Instruction manual. 2ms (rate 2.5Mbps).
According to the transmission distance, the transmission rate is selected from 2.5Mbps, 625kbps and 156kbps.
CC-Link/LT from the station does not need any parameter settings.
Only need to set up the transmission speed in the master module, you can use the remote I/O.
I/O control in the first class of open field network module.
CC-Link based on reliable field bus technology,
Able to transmit large number of bits data (such as ON/OFF information) and word data (such as analog information) MITSUBISHI Q3MEM-4MBS Instruction manual.
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmission) communication separately, so as to ensure the timeliness of.
Even if the information reaches saturation, it will not affect the link scan time.Input: 4 channels.
Thermocouple (C1602~1995 JIS).
Micro voltage (-100mV~100mV).
Conversion speed: (sampling period x3) /1 channel.
18 point terminal station.
Most suitable for process control of isolated analog modules.
Temperature data can be collected by connecting thermocouple / thermal resistance.
Products can choose multi-channel (8 channel) input type and channel isolation type.
Customers can choose the most suitable model according to the intended use.
Auto backup key data
Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
To prevent the loss of the program and the parameters due to forgetting to replace the battery.
In addition, the soft component data and other important data can be backed up to the standard ROM,
In order to avoid during the long holiday and other planned downtime,
The data is lost due to battery depletion.
The next time the power is turned on, the backup data will be automatically restored.
Reduce system downtime recovery time.
With a simple operation, you can back up all the data in the CPU to the memory card.
TThrough regular backup, can be the latest parameters, procedures, etc Q3MEM-4MBS Manual. to save the storage card.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage ccard in advance Q3MEM-4MBS Manual.
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown.
Related products
MITSUBISHI
Memory card
Q3MEM-8MBS
MITSUBISHI Memory card Q3MEM-8MBS
SRAM memory card capacity: 8M ytes. Su
MITSUBISHI
Memory card
Q3MEM-4MBS
MITSUBISHI Memory card Q3MEM-4MBS
SRAM memory card, capacity: 4M ytes. Si
MITSUBISHI
Extended SRAM card
Q4MCA-4MBS
MITSUBISHI Extended SRAM card Q4MCA-4MBS
Extended SRAM card 4MB Simply insert the