"Maximum control axis: 16 axis.
Connection mode with servo amplifier: SSCNET III /H connection type.
The maximum distance between the drive units: 100m.
Operation cycle: 0.88ms, 1.77ms.
Interpolation function: linear interpolation (maximum 4 axis), 2 axis arc interpolation.
Color signal: 4 points.
Color detecting set: 16 set MITSUBISHI Q173NCCPU-S01 Programming Manual .
Even the long distance wiring can be flexible
Q173NCCPU-S01
The use of fiber optic cable, with high speed, high performance, high reliability of the servo system controller network.
In addition to the traditional positioning control, but also to support speed / torque control and synchronous control.
Use simple movement module setup tool",
Can easily perform positioning settings, monitoring and debugging, etc MITSUBISHI Q173NCCPU-S01 Programming Manual . .
In addition, the data can be collected and displayed synchronously with the motion controller.
SSCNET III /H connection to save the wiring, the maximum distance between the station up to 100m,
Absolute position system can be easily supported.
The upper limit limit switch, the lower limit switch and the near point block signal are input by the servo amplifier,
Thus greatly reducing wiring MITSUBISHI Q173NCCPU-S01 Programming Manual .
In addition to positioning control and speed control, but also to perform synchronization control, cam control, torque control, touch pressure control, etc..
Positioning module (QD75MH) of the project and the sequence of the previous model is highly compatible with the old model,
The project can be easily applied to the simple motion module (QD77MS). "MODBUS RTU/MODBUS ASCII Master slave station.
RS-232.
RS-422/485.
MODBUS interface module capable of connecting MODBUS compatible device such as temperature regulator, measuring device and so on.
Support MODBUS communication function, and can be compatible with the third party MODBUS to communicate from various station equipment.
Support MODBUS communication functions from the station, can communicate with the third party programmable controller MODBUS master device.
Through the linkage function, the masteer can be connected to the CH1 side (RS-232),
And through the QJ71MB91 and connected to the CH2 side (RS-422/485) of a number of stations for communication Q173NCCPU-S01 Manual.
The RS-232 interface (1 credit on the 1 pass) MODBUS master device withh multiple MODBUS communication from the station equipment Q173NCCPU-S01 Manual. (only QJ71MB91)
Master / slave station functions can be used simultaneously. (only QJ71MT91)