LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> Q173NCCPU
Q173NCCPU Manual MITSUBISHI Q173NCCPU Communication Protocal Reference Manual
Product model: Q173NCCPU
Name: PLC
Brand: MITSUBISHI
Sort: Communication Protocal Reference Manual
File language: English
Meet safety standards: EN954-1 class 4, 13849-1 PL e ISO.
Safe input points: 1 points (2 input).
Start input points: 1.
Input type: N type (positive public end / negative public end input)
Safe output points: 1 points (3 output).
Spring clip terminal.
Additional security system.
Simply connect to the existing CC-LINK, you can add an independent security features MITSUBISHI Q173NCCPU Reference Manual Q173NCCPU
Saving wiring by CC-link connection.
The wiring is not needed in particular to the condition monitoring of the safety relay module, and realizes the wiring of the cabinet and the other provinces.
Visualization of installation status.
Can monitor the safe output, as well as the safety input and the internal state of the relay, in the safety circuit to facilitate the identification of the reasons for the start MITSUBISHI Q173NCCPU Reference Manual. Compact flash memory card.
Capacity: 1GB bytes.Input: 4 channels.
Thermocouple (K, J, T, B, S, E, R, N, U, L, PLlI, W5Re/W26Re,,).
Heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal table x2.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module MITSUBISHI Q173NCCPU Reference Manual.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same time.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs Q173NCCPU Manual.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process Q173NCCPU Manual.
Automatic adjustment of cost (time, material and electrical energy) can be reduced. For 16 point I/O. 0.3 to 1.5mm2 (AWG22 to 16).
Related products
MITSUBISHI
Motion CPU module
Q173HCPU
MITSUBISHI Motion CPU module Q173HCPU
Control axis: maximum 32 axes. Teaching
MITSUBISHI
Sports CPU module (old model)
Q173CPU
MITSUBISHI Sports CPU module (old model) Q173CPU
Control axis: maximum 8 axes. Greater fl
MITSUBISHI
Motion CPU module
Q173HCPU-T
MITSUBISHI Motion CPU module Q173HCPU-T
Control axis: maximum 32 axes. Teaching
MITSUBISHI
CNC numerical control CPU
Q173NCCPU-S01
MITSUBISHI CNC numerical control CPU Q173NCCPU-S01
Set high performance CNC and high speed