LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> Q173HCPU-T
Q173HCPU-T Programming Manual MITSUBISHI Q173HCPU-T MELSAP-L Manual
Product model: Q173HCPU-T
Name: PLC
Brand: MITSUBISHI
Sort: MELSAP-L Programming Manual
File language: English
AC input: 32 points.
Rated current and voltage: AC100 ~ 120V, 10mA (AC100V, 60Hz).
Response time: 25ms.
Input form: 1 points, 32 public ends.
External wiring connections: 38 terminals (terminals sold separately).
Replacement model: AX11.FL-net (OPCN-2) Ver.2.00 interface.
10BASE5/10BASE-T use.
Real time transmission control data, to improve the production efficiency and the value of the equipment to provide support for the high-speed data communication module MITSUBISHI Q173HCPU-T Manual Q173HCPU-T
The high accuracy data that can be synchronized with the sequential scanning to the user program on the PC can be transmitted through the Ethernet.
Realize the previous communication method can not achieve the detailed control of data transmission,
Real time data analysis using user applications,
In order to provide support for improving production efficiency and equipment value MITSUBISHI Q173HCPU-T Manual.
Easy connection programming tool via ethernet.
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings. And there is no need to select the cable, the straight line and the cross line can be used MITSUBISHI Q173HCPU-T Manual.
Therefore, this connection method and the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection.Adapter for mounting DIN guide rail.
For Q32SB, Q33SB, Q35SB, Q33B, Q52B, Q55B, Q63B.Three-phase 4 wire type.
Measuring circuit number: 3 circuits.
Measurement items: power consumption (consumption, regeneration), current, voltage, power, power factor, etc..
Power measurement module product group capable of simply measuring various energy information.
With only one module can be used to measure and power consumption (consumption and regeneration), reactive power, current, voltage, power, power factor and frequency of all kinds of detailed information.
No ladder program can continue to monitor the minimum and maximum values, can also perform 2 types of upper / lower limit alarm.
Only in the ON state can be used to measure the output of the output device.
Therefore, the amount of electricity and the quantity of electricity in the unit of the beat can be obtained during the operation of the equipment.
3 phase 3 wire products can be used to measure up tto 4 circuits in one slot,
3 phase 4 wire products can be used to measure up to 3 circuits,
So the electrical energy measurement can be carried out in a small space by the multi circuit products Q173HCPU-T Programming Manual.
For example, a module ccan be used to measure other loads from the control panel trunk Q173HCPU-T Programming Manual.
In addition, Works2 GX (version 1.90U and higher) can be used to easily set parameters.
Related products
MITSUBISHI
Motion CPU module
Q173HCPU-T
MITSUBISHI Motion CPU module Q173HCPU-T
Control axis: maximum 32 axes. Teaching
MITSUBISHI
Motion CPU module
Q172HCPU-T
MITSUBISHI Motion CPU module Q172HCPU-T
Control axis: maximum 8 axes. Teaching r
MITSUBISHI
Motion CPU module
Q173HCPU
MITSUBISHI Motion CPU module Q173HCPU
Control axis: maximum 32 axes. Teaching