Redundant CPU data tracking cable length of 3 meters.
Can only be used for MITSUBISHI Q series PLC redundancy CPU.Input points: 16 points.
Input voltage and current: 6mA DC24V.
Response time: 0/0.1/0.2/0.4/0.6/1ms.
16 point /1 a public side.
Common anode.
18 point terminal station.
Easy connection programming tool via ethernet MITSUBISHI Q172DCPU Programming Manual .
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings
Q172DCPU And there is no need to select the cable, the straight line and the cross line can be used.
Therefore, this connection method and the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection MITSUBISHI Q172DCPU Programming Manual .
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields MITSUBISHI Q172DCPU Programming Manual .
Can also be used in combination with the CPU module to achieve appropriate control.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function.
Can be set up to 32 characters of the file password.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password.
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights.Battery replacement.
Initial voltage 3.0V.
Base of large capacity battery.
Current capacity: 5000mAh.
Service life: 5 years.Empty cover plate for I/O groove.For 16 point I/O. 0.3 to 1.5mm2 (AWG22 to 16).Input voltage range: AC100-240V.
Output voltage: DC5V/24V.
Output power: 0.6A.
Simplified program debugging.
Can use the software with the implementation of the conditions of the test function, any step in the program,
Changes the value of the soft component to a user specified value.
In the past, when debugging the specific loop process, the need to add a set of soft components of the program,
At present, through the use of the function, no need to change the program, you can make a specific loop program segment execution action.
Therefore, do not need to change the program separately in order to debug, debugging operation is more simple.
Through the expansion of soft components, more convenient to create the program.
M soft components and B soft components can be expanded to 60K points, making the program easier to understand.
Auto backup key data.
Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
To prevent the loss of the program and the parameters due to forgetting to replace the battery Q172DCPU Manual.
In addition, the soft component data and other important data can be backed up to the standard ROM,
In order to avoid during the long holiday and oother planned downtime,
The data is lost due to battery depletion Q172DCPU Manual.
The next time the power is turned on, the backup data will be automatically restored.