Output points: 16 points.
Output voltage and current: 24V/AC240V 2A/1; DC point; 8A/1 common end.
Response time: 12ms.
16 points / a common end.
18 point spring clip connection terminal.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function.
Can be set up to 32 characters of the file password MITSUBISHI MOTION CONTROLLERS User's Manual.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password
Q172CPUN
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights MITSUBISHI MOTION CONTROLLERS User's Manual.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields MITSUBISHI MOTION CONTROLLERS User's Manual.
Can also be used in combination with the CPU module to achieve appropriate control.
Easy connection programming tool via ethernet.
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings Q172CPUN User's Manual. And there is no need to select the cable, the straight line and the cross line can be used Q172CPUN User's Manual.
Therefore, this connection method and the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection.Input: 4 channels.
Thermocouple (K, J, T, B, S, E, R, N, U, L, PLlI, W5Re/W26Re,,) Q172CPUN User's Manual.
Heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal table x2.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same time.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulatting module has the function of preventing overheating and preventing over cooling Q172CPUN Manual .
According to the control object device, select the standard control (heating or cooling) or the heating and cooling contrrol (heating and cooling) mode MITSUBISHI MOTION CONTROLLERS User's Manual.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.