Q06CCPU-V-H01 Manual MITSUBISHI PLC Q06CCPU-V-H01 Common Instruction 1/2 Programming Manual
Product model: Q06CCPU-V-H01
Name: PLC
Brand: MITSUBISHI
Sort: Common Instruction 1/2 Programming Manual
File language: English
Manual pulse generator /INC synchronous encoder input:
Use number: 3 sets of /1 modules.
Automatically transfer the record file to the FTP server
Simply by recording the configuration tool to carry out a simple setup,
A data record file stored on the SD memory card can be sent to the FTP server.
Because the record server can handle multiple files, it can reduce the task of management and maintenance MITSUBISHI PLC Programming Manual Q06CCPU-V-H01
When a failure occurs, it can quickly respond to.
Simply extract the data associated with the problem, do not have to spend a lot of time to filter a large number of diagnostic data,
So it can quickly determine the cause of the failure, and make the solution.Input: 4 channels.
Thermocouple (K, J, T, B, S, E, R, N, U, L, PLlI, W5Re/W26Re,,) MITSUBISHI PLC Programming Manual.
Heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal table x2.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling MITSUBISHI PLC Programming Manual.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected Q06CCPU-V-H01 Programming Manual.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost Q06CCPU-V-H01 Programming Manual.
Heating function at the same time.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs Q06CCPU-V-H01 Programming Manual.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process.
Automatic adjustment of cost (time, material and electrical energy) can be reduced. Extended SRAM card 1MB.
Support SD memory card.
High speed universal QCPU support SD memory card,
In order to be able to have a memory card port between SD andd PC to easily realize data exchange Q06CCPU-V-H01 Manual.
In addition, the SD memory card and the extended SRAM card can be used simultaneously.
Therefore, the extension of the file register using the extended SRAM card,
SD memory cardd can be used at the same time to carry out the data file record, a large number of annotation data storage, through the memory card to guide operation MITSUBISHI PLC Programming Manual.
Related products
MITSUBISHI
C language CPU
Q06CCPU-V-H01
MITSUBISHI C language CPU Q06CCPU-V-H01
Input / output points: 4096 points. You
MITSUBISHI
C language CPU
Q06CCPU-V
MITSUBISHI C language CPU Q06CCPU-V
Input / output points: 4096 points. You
MITSUBISHI
C language CPU
Q06CCPU-V-B
MITSUBISHI C language CPU Q06CCPU-V-B
Input / output points: 4096 points. You