LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> Q03UDCPU
Q03UDCPU Manual MITSUBISHI PLC Q03UDCPU Special Instructions Programming Manual
Product model: Q03UDCPU
Name: PLC
Brand: MITSUBISHI
Sort: Special Instructions Programming Manual
File language: English
Control axis: maximum 32 axes.
Teaching running function: there (when using SV13).
To stop the speed control function at the specified location.
The servo motor can rotate at a predetermined speed,
After starting the specified location to stop the instruction,
Can be set in advance to stop the location MITSUBISHI PLC Programming Manual.
You can change the speed by changing the value of the options at the time of the operation,
You can also change the acceleration / deceleration time Q03UDCPU
Phase compensation function.
The mixed function of virtual mode and real mode.
Smooth clutch linear acceleration / deceleration function.SRAM+E2PROM memory card.
RAM capacity: 64KB.
E2PROM capacity: 64KB. Twisted pair cable.
Single bus.
Controller network (control station / common station) MITSUBISHI PLC Programming Manual.
MELSECNET/H network module capable of composing large scale flexible network system.
The MELSECNET/H network system includes the PLC network of the control station and the communication between the stations and the remote I/O network in the remote station remote I/O station.
Optical fiber loop system...... High speed communication of 10Mbps/25Mbps is realized MITSUBISHI PLC Programming Manual.
The distance between stations, the length of the total cable length, strong anti-interference.
Coaxial bus system...... Using low cost coaxial cable, the network construction cost is lower than that of the optical fiber loop network Q03UDCPU Programming Manual.
Twisted pair bus system...... Combined with high performance price ratio network module and twisted pair cable,
The construction cost of network system is very low Q03UDCPU Programming Manual. Board module installation location: QS series power module mounting slot.
Suitable substrate module: QS034B.
Input power: AC200~240V.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system Q03UDCPU Programming Manual.
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards.
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also be processed outside the standard ccontrol procedures Q03UDCPU Manual.
All the components in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memoryy,
Output is only when the processing result is in full agreement,
If any inconsistency occurs during the process, the system is immediately shut down MITSUBISHI PLC Programming Manual.
Related products
MITSUBISHI
With Ethernet CPU
Q03UDECPU
MITSUBISHI With Ethernet CPU Q03UDECPU
Input / output points: 4096 points. Num
MITSUBISHI
General purpose CPU
Q03UDCPU
MITSUBISHI General purpose CPU Q03UDCPU
Input / output points: 4096 points. Num
MITSUBISHI
Motion CPU module
Q172DCPU
MITSUBISHI Motion CPU module Q172DCPU
Control axis: maximum 8 axes. Peripheral
MITSUBISHI
Motion CPU module
Q173DCPU
MITSUBISHI Motion CPU module Q173DCPU
Control axis: maximum 32 axes. Manual pu