LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> Q00UCPU
Q00UCPU Programming Manual MITSUBISHI Q00UCPU Common Instruction 1/2 Manual
Product model: Q00UCPU
Name: PLC
Brand: MITSUBISHI
Sort: Common Instruction 1/2 Programming Manual
File language: English
Input points: 8 points (dual input), 16 points (single input).
Isolation mode: photoelectric coupling.
Rated input voltage: DC24V.
Output points: 4 points (select the source type + drain type), 2 points (when selecting the source type + source).
Isolation mode: photoelectric coupling.
Rated input voltage: DC24V MITSUBISHI Q00UCPU Manual.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system Q00UCPU
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards MITSUBISHI Q00UCPU Manual.
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also be processed outside the standard control procedures.
All the components in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memory,
Output is only when the processing result is in full agreement,
If any inconsistency occurs during the process, the system is immediately shut down MITSUBISHI Q00UCPU Manual. Q series of basic conversion module, A series of additional basic unit connection adapter unit.
Suitable for: A5 - B/A6 - B.Board module installation location: QS series power module mounting slot.
Suitable substrate module: QS034B.
Input power: AC100~120V.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system.
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards.
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also be processed outside the staandard control procedures Q00UCPU Programming Manual.
All the components in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memoryy,
Output is only when the processing result is in full agreement,
If any inconsistency occurs during the process, the system is immediately shut down Q00UCPU Programming Manual.
Related products
MITSUBISHI
Programmable logic controller CPU
R32ENCPU
MITSUBISHI Programmable logic controller CPU R32ENCPU
Operation control mode: stored procedure
MITSUBISHI
Motion controller
Q172DSCPU
MITSUBISHI Motion controller Q172DSCPU
Control axis: up to 16 axes. Servo ampli
MITSUBISHI
Motion CPU module
Q173DCPU
MITSUBISHI Motion CPU module Q173DCPU
Control axis: maximum 32 axes. Manual pu