AC input: 32 points.
Rated current and voltage: AC100 ~ 120V, 10mA (AC100V, 60Hz).
Response time: 25ms.
Input form: 1 points, 32 public ends.
External wiring connections: 38 terminals (terminals sold separately).
Replacement model: AX11.5 slots.
No need for power.
Used to install large Q series modules Q50UDEHCPU Manual .
Reduce system downtime recovery time.
With a simple operation, you can back up all the data in the CPU to the memory card
Q50UDEHCPU
Through regular backup, can be the latest parameters, procedures, etc. to save the storage card.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage card in advance.
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown Q50UDEHCPU Manual .
Wider application range, more advanced.
Leading in the era of the Q series CPU products.
Q series CPU products a wide range of applications,
Provide programmable controller, process, redundancy, C language, movement, manipulator, CNC all kinds of CPU,
In order to meet the needs of various control Q50UDEHCPU Manual .
Through the multi CPU configuration, can be based on the use of the scale, purpose,
Construction of the best system to meet the requirements of all kinds of control.
In addition, the high reliability system can be constructed by the redundant system,
Even if a fault occurs, the system can continue to run MITSUBISHI Q50UDEHCPU Programming Guide Book. Input: 4 channels.
Thermocouple (K, J, T, B, S, E, R, N, U, L, PLlI, W5Re/W26Re,,).
Heater disconnection detection function MITSUBISHI Q50UDEHCPU Programming Guide Book.
Sampling period: 0.5s/4 channel.
18 point terminal table x2.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same time MITSUBISHI Q50UDEHCPU Programming Guide Book.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machinee,
The temperature regulating module has the function of preventing overheating and preventing over cooling Q50UDEHCPU Structured Text.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling contrrol (heating and cooling) mode Q50UDEHCPU Manual .
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.