LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> Q4ACPU
PLC Q4ACPU Fundamental Programming Manual MITSUBISHI Q4ACPU Manual
Product model: Q4ACPU
Name: PLC
Brand: MITSUBISHI
Sort: Fundamental Programming Manual
File language: English
Extended SRAM card 4MB
Simply insert the SD memory card, you can automatically record.
Simply insert the SD in the CPU to save the record setting file, you can automatically start recording.
Even when remote data collection is required,
After receiving a record setting file by mail and copy it to the SD memory card,
Can immediately start recording Q4ACPU Programming Manual. Control axis: maximum 32 axes Q4ACPU
Compact size and space saving.
Using the same hardware structure and MELSEC-Q series PLC, to achieve the same product installation area, the size of the industry.
Using 12 slot substrate, more space and cost savings.
Can share PLC MELSEC-Q power module, substrate, and I/O module.
The control process can be assigned to each CPU module in the multi CPU system, which is equivalent to the intelligent control system Q4ACPU Programming Manual.
In PC (Computer Personal) CPU.Extended SRAM card 2MB
Better user experience data recording function.
Easy to record, no need to program.
Simply through the special configuration tool wizard to easily complete the settings,
The collected data can be saved in CSV format to SD storage card.
Can be effectively used to save the CSV file to facilitate the creation of a variety of reference materials,
Including daily reports, generate reports and general reports Q4ACPU Programming Manual.
These data can be applied to the data analysis, tracing, etc. MITSUBISHI Q4ACPU Manual . Control mode: loop program execution.
Input / output control mode: refresh mode.
Programming language: ladder diagram, function block.
Processing speed (CIS): 0 MITSUBISHI Q4ACPU Manual . 10 s.
Program capacity: 14k step.
Security PLC (secure programmable system) refers to the self or external components or the implementation of the failure of the agency,
Can still respond to and promptly cut off the output of the programmable system.
Different from ordinary PLC, security PLC not only can provide the function of ordinary PLC,
Safe control function can be realized,
Meet the requirements of the ISO 13849-1 EN and IEC 61508 control system safety related component standards MITSUBISHI Q4ACPU Manual .
PLC security market mainstream has oilz (Pilz) PSS 3000, PSS 4000,
PSS 4000 in addition to the security process can also be processed outside the sttandard control procedures Q4ACPU Fundamental.
All the components in the security PLC adopt the redundancy structure,
Two processor processing for cross detection,
The processing results of each processor are stored in their respective memoryy,
Output is only when the processing result is in full agreement,
If any inconsistency occurs during the process, the system is immediately shut down Q4ACPU Programming Manual.
Related products
MITSUBISHI
Process CPU
Q12PHCPU
MITSUBISHI Process CPU Q12PHCPU
Program capacity: 124 K step. Input / ou
MITSUBISHI
General purpose CPU
Q02UCPU
MITSUBISHI General purpose CPU Q02UCPU
Input / output points: 2048 points. Num
MITSUBISHI
High performance CPU
Q12HCPU
MITSUBISHI High performance CPU Q12HCPU
Program capacity: 124 K step. Input / ou
MITSUBISHI
CPU unit
Q3ACPU
MITSUBISHI CPU unit Q3ACPU
Input and output points: 2048 points. In