LK Automation Limited LK Automation Limited
Download Sort: OMRON | MITSUBISHI | Proface | Mennekes | Yaskawa
Manual Download >> Q25PHCPU
PLC Q25PHCPU Special Instructions Programming Manual MITSUBISHI Q25PHCPU Manual
Product model: Q25PHCPU
Name: PLC
Brand: MITSUBISHI
Sort: Special Instructions Programming Manual
File language: English
Application: extension.
Suitable for safety standards: EN954-1 class 4, PLe ISO13849-1.
Security input points: 1.
Use special setting monitoring tools to configure the configuration directly.
Constitute a rich set of components can be easily and quickly set the hardware structure.
Creating logic for security devices, by using the automatically generated labels of the FB can easily create logic Q25PHCPU Programming Manual Q25PHCPU
Logical import and export.
You can store the connection settings of the input and output modules and the application logic created by the function block as a setting file,
Or read from a saved set file. Control axis: maximum 8 axes.
Peripheral I/F: by CPU PLC.
Manual pulse generator operation function: can use 3 sets of manual pulse generator Q25PHCPU Programming Manual.
Synchronous encoder operation function: can use 8 synchronous encoder.
CPU special high speed communication bus, each 0.88ms cycle can exchange 14K data word.
Exercise basic performance is about 2 times, sports SFC processing time is reduced by about 1/4.
PLC interrupt program to achieve high-speed synchronization between multiple CPU.
Motion specific instruction Q25PHCPU Programming Manual. Input / output points: 4096 points.
You can use the CF card.
Version OS:VxWorks 5.4.
Simply insert the SD memory card, you can automatically record.
Simply insert the SD in the CPU to save the record setting file, you can automatically start recording MITSUBISHI Q25PHCPU Manual .
Even when remote data collection is required,
After receiving a record setting file by mail and copy it to the SD memory card,
Can immediately start recording MITSUBISHI Q25PHCPU Manual .
Automatically transfer the record file to the FTP server
Simply by recording the configuration tool to carry out a simple setup,
A data record file stored on the SD memory card can be sent to the FTP server.
Because the record server can handle multiple files, it can reduce the task of management and maintenance MITSUBISHI Q25PHCPU Manual .
When a failure occurs, it can quickly respond to.
Simply extract the data associated with the problem, do not have to spend a lot of time to filter a large number of diagnostic data,
So it can quickly determine the cause of the failure, and make the solution.8 channels.
Input: AC0~5A AC0~50A, CT, AC0~100 until AC0~600A.
Output: 0~10000.
18 point terminal.
Directly connected to the CT sensor, saving wiring and space of the CT input module.
Directly connected with CT sensor and programmable controller,
No need for external connection signal converter, etc..
Very accurate measurement results can be obtained by stable data transfer speed,
Then, load control and operation of the system and equipment are carried out, and the power supply system is managed and monitored.
Directly connect the CT sensor, saving wiring and space
In the case of no external signal converter, directly connected to the CT sensor.
A module can be used to measure up to 8 channels of alternating current, thereby reducing wiring time and cost.
Set the CT sensor type (input range) for each channel.
Through a module to select from AC0 ~ 5A to 600A ~ CT AC0 sensor.
Preventive maintenance can be carried out by detecting the peak current.
Peak current detection function
By detecting the peak current, the equipment can perform maintenance and troubleshooting.
Take the motor as an example, the load applied on the motor changes due to wear and damage of the gear,
Load current will suddenly change. Q25PHCPU Special Instructions.
By detecting the transient peak current at this time, the fault of the equipment can be diagnosed.
Input signal error detection function
Can detect whether the CT input value is out of range (higher than the peak value)) Q25PHCPU Programming Manual.
Because the large current flow on the measurement object is beyond the range limit,
Therefore, the error of the measurement object can be monitored.
Related products
MITSUBISHI
Process CPU
Q25PRHCPU
MITSUBISHI Process CPU Q25PRHCPU
Program capacity: 252 K step. Input / ou
MITSUBISHI
With Ethernet CPU
Q10UDEHCPU
MITSUBISHI With Ethernet CPU Q10UDEHCPU
Input / output points: 4096 points. Num
MITSUBISHI
Motion CPU module
Q173HCPU
MITSUBISHI Motion CPU module Q173HCPU
Control axis: maximum 32 axes. Teaching
MITSUBISHI
CPU component
A1SJHCPU
MITSUBISHI CPU component A1SJHCPU
I/O control method: refresh mode or dire