"X 10BASE-T/100BASE-T 1 channel.
No need to use PC to meet all the recording needs of the high-speed data recorder module.
High speed, simple, low cost, the accuracy of data records beyond the past.
Can be used to guide the form of a simple set of high speed data recorder module configuration tool",
And display the collected data with the trend chart,
Help to carry out data analysis, etc Q173DSCPU Manual
Q173DSCPU the recording data display / analysis tool "LogViewer GX"".
By accumulating all kinds of data in the production process,
Not only can help improve the quality of products, reduce production costs, but also for the optimization of the system,
Contribute to the construction of an efficient production site. "8 channels Q173DSCPU Manual .
Input: AC0~5A AC0~50A, CT, AC0~100 until AC0~600A.
Output: 0~10000.
18 point terminal.
Directly connected to the CT sensor, saving wiring and space of the CT input module.
Directly connected with CT sensor and programmable controller,
No need for external connection signal converter, etc..
Very accurate measurement results can be obtained by stable data transfer speed,
Then, load control and operation of the system and equipment are carried out, and the power supply system is managed and monitored Q173DSCPU Manual .
Directly connect the CT sensor, saving wiring and space
In the case of no external signal converter, directly connected to the CT sensor.
A module can be used to measure up to 8 channels of alternating current, thereby reducing wiring time and cost MITSUBISHI Q173DSCPU Programming Guide Book.
Set the CT sensor type (input range) for each channel MITSUBISHI Q173DSCPU Programming Guide Book.
Through a module to select from AC0 ~ 5A to 600A ~ CT AC0 sensor.
Preventive maintenance can be carried out by detecting the peak current.
Peak current detection function
By detecting the peak current, the equipment can perform maintenance and troubleshooting.
Take the motor as an example, the load applied on the motor changes due to wear and damage of the gear,
Load current will suddenly change MITSUBISHI Q173DSCPU Programming Guuide Book Q173DSCPU Structured Text.
By detecting the transient peak current at this time, the fault of the equipment can be diagnosed.
Input signal error detection function
Can detect whether the CT input value is out of range (higher than the peak value)) Q173DSCPU Manual .
Because the large current flow on the measurement object is beyond the range limit,
Therefore, the error of the measurement object can be monitored.