PLC Q06CCPU-V-H01 Structured Text(ST) Programming Guide Book MITSUBISHI Q06CCPU-V-H01 Manual
Product model: Q06CCPU-V-H01
Name: PLC
Brand: MITSUBISHI
Sort: Structured Text(ST) Programming Guide Book
File language: English
Input voltage range: AC100-240V.
Output voltage: DC5V.
Output power: 8.5A.
Simplified program debugging
Can use the software with the implementation of the conditions of the test function, any step in the program,
Changes the value of the soft component to a user specified value.
In the past, when debugging the specific loop process, the need to add a set of soft components of the program,
At present, through the use of the function, no need to change the program, you can make a specific loop program segment execution action Q06CCPU-V-H01 Programming Guide Book Q06CCPU-V-H01
Therefore, do not need to change the program separately in order to debug, debugging operation is more simple.
Auto backup key data
Save the program and parameter files automatically to the program memory (ROM Flash) without using the backup battery,
To prevent the loss of the program and the parameters due to forgetting to replace the battery Q06CCPU-V-H01 Programming Guide Book.
In addition, the soft component data and other important data can be backed up to the standard ROM,
In order to avoid during the long holiday and other planned downtime,
The data is lost due to battery depletion.
The next time the power is turned on, the backup data will be automatically restored Q06CCPU-V-H01 Programming Guide Book.
Through the expansion of soft components, more convenient to create the program.
M soft components and B soft components can be expanded to 60K points, making the program easier to understand MITSUBISHI Q06CCPU-V-H01 Manual. Input: 4 channels.
Thermocouple (K, J, T, B, S, E, R, N, U, L, PLlI, W5Re/W26Re,,).
No heater disconnection detection function MITSUBISHI Q06CCPU-V-H01 Manual.
Sampling period: 0.5s/4 channel.
18 point terminal station.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost.
Heating function at the same time MITSUBISHI Q06CCPU-V-H01 Manual.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling Q06CCPU-V-H01 Structured Text(ST).
According to the control object device, select the standard control (heating or cooling) or the heating and cooling contrrol (heating and cooling) mode Q06CCPU-V-H01 Programming Guide Book.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
Related products
MITSUBISHI
C language CPU
Q06CCPU-V
MITSUBISHI C language CPU Q06CCPU-V
Input / output points: 4096 points. You
MITSUBISHI
C language CPU
Q06CCPU-V-B
MITSUBISHI C language CPU Q06CCPU-V-B
Input / output points: 4096 points. You
MITSUBISHI
C language CPU
Q06CCPU-V-H01
MITSUBISHI C language CPU Q06CCPU-V-H01
Input / output points: 4096 points. You