PLC L02CPU-CM Common Instruction 1/2 Manual MITSUBISHI L02CPU-CM Programming Manual
Product model: L02CPU-CM
Name: PLC
Brand: MITSUBISHI
Sort: Common Instruction 1/2 Programming Manual
File language: English
Input power: AC100-240V.
Output: DC5V, 5A.
Power supply module can be directly pasted on the printed circuit board of the power supply,
The device is characterized in that a special integrated circuit (ASIC), a digital signal processor (DSP), a microprocessor, a memory, a field programmable gate array (FPGA), and other digital or analog loads are provided L02CPU-CM Manual.
In general, this type of module is called the load point (POL) power supply system or the use of point power supply system (PUPS) L02CPU-CM
Because of the advantages of the modular structure,
The module power supply is widely used in switching devices, access devices, mobile communications, microwave communications and optical transmission, routers and other communication fields and automotive electronics, aerospace, etc L02CPU-CM Manual. . Control axis: maximum 2 axes.
Operation cycle: 0.88ms.
Interpolation function: linear interpolation (maximum 4 axis), 2 axis arc interpolation.
Color signal: 2 points.
Color detecting set: 4 set.
Only need to use the PLC program can easily achieve synchronous control, cam control, speed and torque (push pressure control) and other advanced motion control L02CPU-CM Manual.
Equipped with standard synchronous encoder and color detection function necessary function.
Can be no procedures for setting. Strong support for MELSOFT.
Can fully apply LD77MH of the old program.
Let motion control more simple. Thermocouple input MITSUBISHI L02CPU-CM Programming Manual.
Number of input channels: 4ch.
Detection function of broken wire with heater.
Standard control.
Heating and cooling control MITSUBISHI L02CPU-CM Programming Manual.
Self tuning function.
Peak current suppression.
Heating function at the same time.
Sampling period switching function.
Temperature input mode.
Temperature regulation mode.
To reduce operating costs by saving energy
Peak current suppression
After the peak current suppression function is used, the number of the upper limit output limit of each channel can be changed automatically,
Split transistor output time MITSUBISHI L02CPU-CM Programming Manual. To suppress the peak current.
Restrain the peak current to achieve energy saving effect (reducing the power supply capacity of the equipment, saving the electricity contract), and reduce the operation cost.
Achieve average temperature control
Warming function at the same time
By making the arrival time of the multi loop consistent, uniform temperature control function.
It can control temperature uniform, to ensure that the control object no local burning or thermal expansion.
No idle running, with energy saving effect, can reduce operating costs.
To achieve high stability temperature control
Standard control / heating, cooling control.
The devicce used for the temperature control of the temperature control of the extrusion molding machine can prevent over heating and cooling L02CPU-CM Common Instruction 1/2.
According to the object device can choose any one of the following control method.
Standard controol (heating or cooling) L02CPU-CM Manual.
Heating, cooling control (heating and cooling).
Hybrid control (combination of standard control and heating, cooling control).
Related products
MITSUBISHI
cpu module
L02CPU-CM
MITSUBISHI cpu module L02CPU-CM
"Universal output function: leakage type
MITSUBISHI
cpu module
L26CPU-CM
MITSUBISHI cpu module L26CPU-CM
"Universal output function: leakage type
MITSUBISHI
cpu module
L06CPU-CM
MITSUBISHI cpu module L06CPU-CM
"Universal output function: leakage type
MITSUBISHI
cpu module
L02SCPU-CM
MITSUBISHI cpu module L02SCPU-CM
"Universal output function: leakage type