PLC FX3U-64MT/DSS Hardware Edition USER'S MANUAL MITSUBISHI FX3U-64MT/DSS Manual
Product model: FX3U-64MT/DSS
Name: PLC
Brand: MITSUBISHI
Sort: Hardware Edition USER'S MANUAL
File language: English
MITSUBISHI inverter FR-F740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 400KW.
The main circuit of the inverter can be divided into two categories in general: voltage type is the voltage source of the DC converter for AC inverter,
The filtering of the DC circuit is the capacitance; the current mode is the DC conversion of the current source to the AC inverter,
The DC loop filter is the inductor FX3U-64MT/DSS USER'S MANUAL FX3U-64MT/DSS
Why is the frequency of the inverter voltage proportional to the change?
The electromagnetic torque of any motor is the result of the interaction between the current and the magnetic flux, the current is not allowed to exceed the rated value, otherwise it will cause the heating of the motor FX3U-64MT/DSS USER'S MANUAL.
Therefore, if the magnetic flux decreases, the electromagnetic torque will decrease, which leads to the reduction of the load carrying capacity. The analog input adapter (FX3U- - racy -BD)Max input / output points: 64 points.
Supply voltage: 100 - 240VAC.
Input points: 32 points.
Output points: 32 points.
Output type: Transistor (sinktype).
Power consumption: 45W.
Weight (kg):1 FX3U-64MT/DSS USER'S MANUAL. 0.
Size (WxHxD) mm:220x90x86.
Faster and more efficient. Support high speed control and network communication, and have the function of data recording.
High speed, large capacity, multi-function high-end machine.
FX3U supports high speed processing, CC-Link communication, network communication, analog control and advanced positioning system MITSUBISHI FX3U-64MT/DSS Manual.
Connected to the CC-Link, including the remote I/O, the maximum input and output control points up to 384 points,
Can correspond to a variety of field needs, the use of its scalability and flexibility to expand the scope of application of the control system MITSUBISHI FX3U-64MT/DSS Manual.
Third generation high function micro programmable controller.
High speed, high efficiency, high performance, large capacity, and new features MITSUBISHI FX3U-64MT/DSS Manual.
Built in high speed processing and positioning.
Control points: maximum 256 points.
Use CC-Link remote I/O for 384 points. "MITSUBISHI inverter FR-F740P series.
Voltage level: three phase 400V.
Frequency converter capacity: 11KW.
It is based on the overall effect of three-phase waveform generation,
In order to approach the ideal circular rotating magnetic field in the air gap of the motor,
A generation phase modulation waveform control inscribesthe polygon to approach the circle way.
After practice, it has been improved, that is, the introduction of frequency compensation, can eliminate the error of speed control;
By feedback estimation of flux amplitude, eliminating the influence of stator resistance at low speed, the output voltage and current closed loop,
In order to improve the accuracy and stability of the dynamic.
But there are many control circuit, and no torque is introduced, so the system performance has not been improved.
Frequency converter is a power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency,
The equipment to the power of the AC power conversion to DC (DC), the process is called rectification.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter.
Inverter output waveform is simulated sine wave,
Is mainly used in three-phase asynchronous motor speed control, and also called frequency governor.
For the variable frequency inverter, which is mainly uused in the testing equipment of instrument and meter,
To sort out the waveform, you can output the standard sine wave, called the inverter power supply FX3U-64MT/DSS Hardware Edition.
The general inverter is 1520 times inverter price.
The main device called "inverter" because of the voltage or frequency of the inverter device ",
Therefore, the product itself is named "inverter", that is: inverter FX3U-64MT/DSS USER'S MANUAL. "
Related products
MITSUBISHI
PLC
FX3GC-32MT/DSS
MITSUBISHI PLC FX3GC-32MT/DSS
Input and output points: 32 points. Powe
MITSUBISHI
PLC
FX3GE-24MT/DSS
MITSUBISHI PLC FX3GE-24MT/DSS
Input and output points: 24 points. Powe
MITSUBISHI
PLC
FX3U-64MT/ES-A
MITSUBISHI PLC FX3U-64MT/ES-A
Max input / output points: 64 points. Su
MITSUBISHI
PLC
FX3GE-40MT/DSS
MITSUBISHI PLC FX3GE-40MT/DSS
Input and output points: 40 points. Powe