PLC FX3U-32MT/DS Hardware Edition USER'S MANUAL MITSUBISHI FX3U-32MT/DS Manual
Product model: FX3U-32MT/DS
Name: PLC
Brand: MITSUBISHI
Sort: Hardware Edition USER'S MANUAL
File language: English
Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Analog input expansion board (2 channel).Max input / output points: 32 points.
Power supply voltage: 24VDC.
Input points: 16 points.
Output points: 16 points.
Output type: Transistor (sink).
Power consumption: 8W FX3U-32MT/DS USER'S MANUAL.
Weight (kg):0.2.
Size (WxHxD) mm:35x90x87.
Taking into account space saving and processing speed FX3U-32MT/DS
Connector input and output type compact high performance universal machine.
Compact, scalable input / output.
Can connect analog quantity, communication, positioning, etc..
Rich special extension equipment for FX2N.
By connecting the compact FX2rvc series with the input and output expansion module FX3U-32MT/DS USER'S MANUAL.
The input and output can be extended to 256 points.
Built in 8000 step RAM memory.
By installing the memory card box, the maximum can be extended to the 16000 step.
Overseas oriented products meet all kinds of international standards.
Use terminal module to replace connector connection or relay terminal row connection,
So as to save the wiring inside the cabinet. MITSUBISHI inverter FR-A740 series FX3U-32MT/DS USER'S MANUAL.
Voltage level: 3 phase 400V.
Frequency converter capacity: 18.5KW.
FR-A700 converter products are suitable for all kinds of high load requirements of the equipment.
Such as lifting, lift, printing and dyeing, printing and dyeing, material coiling and other general occasions MITSUBISHI FX3U-32MT/DS Manual.
High level driving performance.
Unique sensorless vector control mode,
A wide variety of mechanical equipment can be operated at high precision in the super low speed region without the need of the encoder MITSUBISHI FX3U-32MT/DS Manual.
With torque control mode,
And in the speed control mode can use the torque limit function.
With vector control function (with encoder),
Frequency converter can achieve position control and fast response, high precision speed control (zero speed control, servo lock, etc MITSUBISHI FX3U-32MT/DS Manual. ) and torque control. "MITSUBISHI inverter FR-F740P series.
Voltage level: three phase 400V.
Frequency converter capacity: 450KW.
The main circuit of the inverter can be divided into two categories in general: voltage type is the voltage source of the DC converter for AC inverter,
The filtering of the DC circuit is the capacitance; the current mode is the DC conversion of the current source to the AC inverter,
The DC loop filter is the inductor.
It is based on the overall effect of three-phase waveform generation,
In order to approach the ideal circular rotating magnetic field in the air gap of the motor,
A generation phase modulation waveform control inscribesthe polygon to approach the circle way.
After practice, it has been improved, that is, the introduction of frequency compensation, can eliminate the error of speed control;
By feedback estimation of flux amplitude, eliminating the influence of stator resistance at low speed, the output voltage and current closed loop,
In order to improve the accuracy and stability of the dynamic.
But there are many control circuit, and no torque is introduced, so the system performance has not been improved.
Frequency converter is a power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency,
The equipment to the power of the AC power conversion to DC (DC), the process is called rectification.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter.
Inverter output waveform is simulated sine wave,
Is mainly used in three-phase asynchronous motor speed control, and also called frequency governor.
For the variable frequency inverter, which is mainly used in the testing equipment of instrument and meter,
To sort out the waveform, you can output the standard sine wave, called the inverter power supply FX3U-32MT/DS Hardware Edition.
The general inverter is 1520 times inverter price.
The main device called "inverter" because of the voltage or frequency of the inverter device ",
Therefore, the product itself is named "inverter", that is: inverter FX3U-32MT/DS USER'S MANUAL. "
Related products
MITSUBISHI
PLC
FX3U-32MR/ES-A
MITSUBISHI PLC FX3U-32MR/ES-A
Max input / output points: 32 points. Su
MITSUBISHI
PLC
FX3GC-32MT/DSS
MITSUBISHI PLC FX3GC-32MT/DSS
Input and output points: 32 points. Powe
MITSUBISHI
PLC
FX3U-32MT/DSS
MITSUBISHI PLC FX3U-32MT/DSS
Max input / output points: 32 points. Po
MITSUBISHI
PLC
FX3U-32MT/ESS
MITSUBISHI PLC FX3U-32MT/ESS
Max input / output points: 32 points. Su