Analog output expansion board (1 channel).
Can be installed in FX1N, PLC FX1S, providing 1 channel analog input of the board.
Because it is embedded in the PLC installation, so do not need to install space.
Can easily control the speed of the inverter. Max input / output points: 48 points.
Supply voltage: 100 - 240VAC F1-20MR-UL Manual.
Input points: 24 points.
Output points: 24 points.
Output type: transistor
F1-20MR-UL
Power consumption: 50VA.
Weight (kg):0.85.
Size (WxHxD) mm:182x90x87.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation.
RUN/STOP switch, running on panel / stop switch easy to operate F1-20MR-UL Manual.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, using a eight digit password to protect your program.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time F1-20MR-UL Manual.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017). Power: 3.7kw.
Purpose: to suppress the power harmonics.
Improve the power factor, reduce the input side of the high harmonic current MITSUBISHI F1-20MR-UL INSTRUCTION MANUAL.
Make sure that this option is installed in the FR-A820-03800 (75K) and FR-A840-02160 (75K) and above capacity and above capacity MITSUBISHI F1-20MR-UL INSTRUCTION MANUAL.
At the same time the installation options in the use of 75kW and above motor. (the IP55 series has a built-in DC reactor.)
According to the motor power used to select the DC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose MITSUBISHI F1-20MR-UL INSTRUCTION MANUAL. ) "Power: 30kw.
Voltage: 400V.
Brake resistor, a kind of ripple resistance, is mainly used in the mechanical system of the inverter to control the speed of the motor,
Help the motor to be converted into heat energy due to the regenerative power of the motor F1-20MR-UL Sink input type.
Braking unit principle: the brake unit is composed of a high power transistor GTR and its driving circuit.
Its function is to link the discharge current braking resistor capacitor voltage or not in the range of the time connsumed and the DC part "overpressure",
Need to add external braking components, in order to speed up the speed of the consumption of renewable energy F1-20MR-UL Manual. "